Comparative Analysis on the Effect of Surface Reflectance for Laser 3D Scanner Calibrator.

Jia Ou, Tingfa Xu, Xiaochuan Gan, Xuejun He, Yan Li, Jiansu Qu, Wei Zhang, Cunliang Cai

Abstract read
In one paragraph

Article in Micromachines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jia OuSchool of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China.
Tingfa XuSchool of Optics and Photonics, Beijing Institute of Technology, Beijing 100081, China.
Xiaochuan GanBeijing Changcheng Institute of Metrology and Measurement, Beijing 100095, China.
Xuejun HeBeijing Changcheng Institute of Metrology and Measurement, Beijing 100095, China.
Yan LiBeijing Changcheng Institute of Metrology and Measurement, Beijing 100095, China.
Jiansu QuBeijing Changcheng Institute of Metrology and Measurement, Beijing 100095, China.
Wei ZhangBeijing Changcheng Institute of Metrology and Measurement, Beijing 100095, China.
Cunliang CaiSchool of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun 130022, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The calibrator is one of the most important factors in the calibration of various laser 3D scanning instruments. The requirements for the diffuse reflection surface are emphasized in many national standards. In this study, spherical calibrator and plane calibrator comparative measurement experiments were carried out. The black ceramic standard sphere, white ceramic standard sphere, metal standard sphere, metal standard plane, and white ceramic standard plane were used to test the laser 3D scanner. In the spherical calibrator comparative measurement experiments, the results indicate that the RMS of the white ceramic spherical calibrator with a reflectance of approximately 60% is 10 times that of the metal spherical calibrator with the reflectance of approximately 15%, and the RMS of the black ceramic spherical calibrator with reflectance of approximately 11% is of the same order as the metal spherical calibrator. In the plane calibrators comparative measurement experiments, the RMS of the flatness measurement is 0.077 mm for the metal plane calibrator with a reflectance of 15%, and 2.915 mm for ceramic plane calibrator with a reflectance of 60%. The results show that when the optimal measurement distance and incident angle are selected, the reflectance of the calibrator has a great effect on the measurement results, regardless of the outlines or profiles. Based on the experiments, it is recommended to use the spherical calibrator or the standard plane with a reflectance of around 18% as the standard, which can obtain reasonable results. In addition, it is necessary to clearly provide the material category and surface reflectance information of the standard when calibrating the scanner according to the measurement standard.

Indexed as

3D scanner calibratorlaser scanning instrumentmeasurement accuracysurface reflectance

Identifiers

PMID36295962
PMCPMC9609854

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.