Evidence map›Paper›PMID 36295926›Full record

ArticleMicromachines2022

PDMS Organ-On-Chip Design and Fabrication: Strategies for Improving Fluidic Integration and Chip Robustness of Rapidly Prototyped Microfluidic In Vitro Models.

Tiffany C Cameron, Avineet Randhawa, Samantha M Grist, Tanya Bennet, Jessica Hua, Luis G Alde, Tara M Caffrey, Cheryl L Wellington, Karen C Cheung

Abstract read
In one paragraph

Article in Micromachines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

21 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Advances in microfluidic chip technology for cell analysis.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2025
    Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Review
  10. Review
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Integration of immune cells in organs-on-chips: a tutorial.Frontiers in bioengineering and biotechnology · 2023
    Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Tiffany C CameronSchool of Biomedical Engineering, University of British Columbia, Vancouver, BC V6T 1Z3, Canada.
Avineet RandhawaSchool of Biomedical Engineering, University of British Columbia, Vancouver, BC V6T 1Z3, Canada.
Samantha M GristSchool of Biomedical Engineering, University of British Columbia, Vancouver, BC V6T 1Z3, Canada.
Tanya BennetSchool of Biomedical Engineering, University of British Columbia, Vancouver, BC V6T 1Z3, Canada.
Jessica HuaSchool of Biomedical Engineering, University of British Columbia, Vancouver, BC V6T 1Z3, Canada.
Luis G AldeCentre for Blood Research, University of British Columbia, Vancouver, BC V6T 1Z3, Canada.
Tara M CaffreySchool of Biomedical Engineering, University of British Columbia, Vancouver, BC V6T 1Z3, Canada.ORCID 0000-0002-7670-7411
Cheryl L WellingtonDepartment of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, BC V6T 2B5, Canada.
Karen C CheungSchool of Biomedical Engineering, University of British Columbia, Vancouver, BC V6T 1Z3, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The PDMS-based microfluidic organ-on-chip platform represents an exciting paradigm that has enjoyed a rapid rise in popularity and adoption. A particularly promising element of this platform is its amenability to rapid manufacturing strategies, which can enable quick adaptations through iterative prototyping. These strategies, however, come with challenges; fluid flow, for example, a core principle of organs-on-chip and the physiology they aim to model, necessitates robust, leak-free channels for potentially long (multi-week) culture durations. In this report, we describe microfluidic chip fabrication methods and strategies that are aimed at overcoming these difficulties; we employ a subset of these strategies to a blood-brain-barrier-on-chip, with others applied to a small-airway-on-chip. Design approaches are detailed with considerations presented for readers. Results pertaining to fabrication parameters we aimed to improve (e.g., the thickness uniformity of molded PDMS), as well as illustrative results pertaining to the establishment of cell cultures using these methods will also be presented.

Indexed as

cell culturemicrofluidicorgan-on-chiprapid prototyping

Identifiers

PMID36295926
PMCPMC9609846

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.