Evidence map›Paper›PMID 36294840›Full record

ArticleJournal of personalized medicine2022

Retrospective Analysis of Doses Delivered during Embolization Procedures over the Last 10 Years.

Joël Greffier, Djamel Dabli, Tarek Kammoun, Jean Goupil, Laure Berny, Ghizlane Touimi Benjelloun, Jean-Paul Beregi, Julien Frandon

Open access · goldAbstract read
In one paragraph

Article in Journal of personalized medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Joël GreffierIMAGINE UR UM 103, Department of Medical Imaging, Montpellier University, Nîmes University Hospital, 30029 Nîmes, France.ORCID 0000-0002-1735-5129
Djamel DabliIMAGINE UR UM 103, Department of Medical Imaging, Montpellier University, Nîmes University Hospital, 30029 Nîmes, France.
Tarek KammounIMAGINE UR UM 103, Department of Medical Imaging, Montpellier University, Nîmes University Hospital, 30029 Nîmes, France.
Jean GoupilIMAGINE UR UM 103, Department of Medical Imaging, Montpellier University, Nîmes University Hospital, 30029 Nîmes, France.
Laure BernyIMAGINE UR UM 103, Department of Medical Imaging, Montpellier University, Nîmes University Hospital, 30029 Nîmes, France.
Ghizlane Touimi BenjellounIMAGINE UR UM 103, Department of Medical Imaging, Montpellier University, Nîmes University Hospital, 30029 Nîmes, France.
Jean-Paul BeregiIMAGINE UR UM 103, Department of Medical Imaging, Montpellier University, Nîmes University Hospital, 30029 Nîmes, France.
Julien FrandonIMAGINE UR UM 103, Department of Medical Imaging, Montpellier University, Nîmes University Hospital, 30029 Nîmes, France.ORCID 0000-0001-7816-8178
Université de Montpellier · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: This study aimed to retrospectively analyze dosimetric indicators recorded since 2012 for thoracic, abdominal or pelvic embolizations to evaluate the contribution of new tools and technologies in dose reduction. Methods: Dosimetric indicators (dose area product (DAP) and air kerma (AK)) from 1449 embolizations were retrospectively reviewed from August 2012 to March 2022. A total of 1089 embolizations were performed in an older fixed C-Arm system (A1), 222 in a newer fixed C-Arm system (A2) and 138 in a 4DCT system (A3). The embolization procedures were gathered to compare A1, A2 and A3. Results: DAP were significantly lower with A2 compared to A1 for all procedures (median −50% ± 5%, p < 0.05), except for uterine elective embolizations and gonadal vein embolization. The DAP values were significantly lower with A3 than with A1 (p < 0.001). CT scan was used for guidance in 90% of embolization procedures. Conclusions: The last C-Arm technology allowed a median reduction of 50% of the X-ray dose. The implementation of a CT scan inside the IR room allowed for more precise 3D-guidance with no increase of the dose delivered.

Indexed as

CT scandose optimizationembolizationinterventional radiology

Identifiers

PMID36294840
PMCPMC9605272
OpenAlexW4304689564

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.