Evidence map›Paper›PMID 36294158›Full record

ArticleInternational journal of environmental research and public health2022

Quantitative Measurement of the Pressure and Shear Stress Acting on the Body of a Wheelchair User Using a Wearable Sheet-Type Sensor: A Preliminary Study.

Satoshi Shirogane, Shigeru Toyama, Motonori Hoshino, Atsushi Takashima, Toshiaki Tanaka

Open access · goldAbstract read
In one paragraph

Article in International journal of environmental research and public health, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
5.0field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Satoshi ShiroganeNational Rehabilitation Center for Persons with Disabilities, 4-1 Namiki, Tokorozawa 359-8555, Saitama, Japan.
Shigeru ToyamaNational Rehabilitation Center for Persons with Disabilities, 4-1 Namiki, Tokorozawa 359-8555, Saitama, Japan.ORCID 0000-0001-8277-9019
Motonori HoshinoNational Rehabilitation Center for Persons with Disabilities, 4-1 Namiki, Tokorozawa 359-8555, Saitama, Japan.
Atsushi TakashimaNational Rehabilitation Center for Persons with Disabilities, 4-1 Namiki, Tokorozawa 359-8555, Saitama, Japan.ORCID 0000-0003-3504-1518
Toshiaki TanakaInstitute of Gerontology, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8654, Japan.ORCID 0000-0002-1195-3945
National Rehabilitation Center for Persons with Disabilities · JPHokkaido University of Science · JP

Funding

JSPS KAKENHI 20H04060
6 · The paper itself

Abstract

To provide a safer sitting environment for wheelchair users, it is important to quantitatively measure the forces acting on the contact surface between the seat and the person in the wheelchair. In addition to the pressure acting on the buttocks, shear forces have received particular attention in recent years; however, measuring shear force is more difficult than measuring pressure. To obtain this measurement, a thin and flexible sensor that can be used in a natural state on a wheelchair is needed. Therefore, we constructed a measurement system using our previously developed wearable sheet-type sensor (0.9 mm thick). In this study, preliminary tests were conducted using human dummies before testing on humans. Sensors were placed in four locations on the humanoid dummy's back and buttocks, and the electric wheelchair was tilted and reclined five times each. The results showed that the sensor output pattern was reproducible and valid enough to proceed to the next step. However, the shear force in the internal and external directions was greater than expected, which indicates that the equipment and testing methods must be reviewed. On the basis of the results obtained in this preliminary study, preparations will be made for testing on human subjects.

Indexed as

Wearable Electronic DevicesWheelchairsEquipment DesignHumansPostureStress, Mechanicalelectric wheelchairpressure ulcershear forcewearable sensor

Identifiers

PMID36294158
PMCPMC9603670
OpenAlexW4306926024

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.