Evidence map›Paper›PMID 36292364›Full record

ArticleHealthcare (Basel, Switzerland)2022

Local Diagnostic Reference Levels for Full-Field Digital Mammography and Digital Breast Tomosynthesis in a Tertiary Hospital in Malaysia.

Norhashimah Mohd Norsuddin, Sharveeni Segar, Rathieswari Ravintaran, Norhayati Mohd Zain, Muhammad Khalis Abdul Karim

Open access · goldAbstract read
In one paragraph

Article in Healthcare (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.6field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 18 citations in OpenAlex.

  1. Article
  2. Local Diagnostic Reference Levels in Digital Breast Tomosynthesis.Journal of medical radiation sciences · 2025
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Norhashimah Mohd NorsuddinCenter for Diagnostic, Therapeutic and Investigative Studies (CODTIS), Faculty of Health Sciences, University Kebangsaan Malaysia, Kuala Lumpur 56000, Malaysia.ORCID 0000-0003-3877-1292
Sharveeni SegarCenter for Diagnostic, Therapeutic and Investigative Studies (CODTIS), Faculty of Health Sciences, University Kebangsaan Malaysia, Kuala Lumpur 56000, Malaysia.
Rathieswari RavintaranCenter for Diagnostic, Therapeutic and Investigative Studies (CODTIS), Faculty of Health Sciences, University Kebangsaan Malaysia, Kuala Lumpur 56000, Malaysia.
Norhayati Mohd ZainMedical Imaging Department, School of Health Sciences, KPJ Healthcare University College, Lot PT 17010, Persiaran Seriemas, Kota Seriemas, Nilai 71800, Malaysia.ORCID 0000-0001-7216-087X
Muhammad Khalis Abdul KarimDepartment of Physics, Faculty of Science, University Putra Malaysia, Serdang 43400, Malaysia.ORCID 0000-0002-5357-4193
KPJ Healthcare UniversityUniversiti Putra Malaysia · MY

Funding

Universiti Kebangsaan Malaysia GGPM-2019-021
6 · The paper itself

Abstract

A set of national diagnostic reference levels (DRLs) was established in Malaysia for a range of breast thicknesses in 2013, but no updates for full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT). Due to the increasing number of DBTs used and concern over radiation exposure, this study aimed to explore and establish local diagnostic reference levels for FFDM and DBT in Malaysia health facilities at different compressed breast thickness (CBT) ranges. The CBT, kilovoltage peak (kVp), Entrance surface dose (ESD), and average glandular dose (AGD) were retrospectively extracted from the mammography Digital Imaging and Communications in Medicine (DICOM) header. The 75th and 95th percentile values were obtained for the AGD distribution of each mammography projection for three sets of CBT range. The difference in AGD values between FFDM and DBT at three CBT ranges was determined. The DRLs for FFDM were 1.13 mGy, 1.52 mGy, and 2.87 mGy, while DBT were 1.18 mGy, 1.88 mGy, and 2.78 mGy at CBT ranges of 20−39 mm, 40−59 mm, and 60−99 mm, respectively. The AGD of DBT was significantly higher than FFDM for both mammographic views (p < 0.005). All three CBT groups showed a significant difference in AGD values for FFDM and DBT (p < 0.005). The local DRLs from this study were lower than the national DRLs, with the AGD of FFDM significantly lower than DBT.

Indexed as

average glandular dosecompressed breast thicknessdiagnostic reference leveldigital breast tomosynthesisfull-field digital mammography

Identifiers

PMID36292364
PMCPMC9601326
OpenAlexW4303685920

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.