Evidence map›Paper›PMID 36292263›Full record

ArticleHealthcare (Basel, Switzerland)2022

Augmented Reality Surgical Navigation System for External Ventricular Drain.

Shin-Yan Chiou, Zhi-Yue Zhang, Hao-Li Liu, Jiun-Lin Yan, Kuo-Chen Wei, Pin-Yuan Chen

Open access · goldAbstract read
In one paragraph

Article in Healthcare (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
2.2field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it, 25 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Augmented Reality in Neurosurgery.Advances in experimental medicine and biology · 2024
    Review
  9. Article
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Shin-Yan ChiouDepartment of Electrical Engineering, College of Engineering, Chang Gung University, Kwei-Shan, Taoyuan 333, Taiwan.ORCID 0000-0001-8182-1676
Zhi-Yue ZhangDepartment of Electrical Engineering, College of Engineering, Chang Gung University, Kwei-Shan, Taoyuan 333, Taiwan.
Hao-Li LiuDepartment of Electrical Engineering, National Taiwan University, Taipei 106, Taiwan.ORCID 0000-0003-3512-7215
Jiun-Lin YanDepartment of Neurosurgery, Keelung Chang Gung Memorial Hospital, Keelung 204, Taiwan.
Kuo-Chen WeiDepartment of Neurosurgery, New Taipei City TuCheng Hospital, New Taipei City 236, Taiwan.ORCID 0000-0003-3505-2196
Pin-Yuan ChenDepartment of Neurosurgery, Keelung Chang Gung Memorial Hospital, Keelung 204, Taiwan.
Chang Gung University · TWKeelung Chang Gung Memorial Hospital · TWNational Taiwan University · TWTaipei City Hospital · TW

Funding

Chang Gung Memorial Hospital BMRPB46Chang Gung Memorial Hospital CMRPD2M0021Ministry of Science and Technology 111-2221-E-182-020
6 · The paper itself

Abstract

Augmented reality surgery systems are playing an increasing role in the operating room, but applying such systems to neurosurgery presents particular challenges. In addition to using augmented reality technology to display the position of the surgical target position in 3D in real time, the application must also display the scalpel entry point and scalpel orientation, with accurate superposition on the patient. To improve the intuitiveness, efficiency, and accuracy of extra-ventricular drain surgery, this paper proposes an augmented reality surgical navigation system which accurately superimposes the surgical target position, scalpel entry point, and scalpel direction on a patient's head and displays this data on a tablet. The accuracy of the optical measurement system (NDI Polaris Vicra) was first independently tested, and then complemented by the design of functions to help the surgeon quickly identify the surgical target position and determine the preferred entry point. A tablet PC was used to display the superimposed images of the surgical target, entry point, and scalpel on top of the patient, allowing for correct scalpel orientation. Digital imaging and communications in medicine (DICOM) results for the patient's computed tomography were used to create a phantom and its associated AR model. This model was then imported into the application, which was then executed on the tablet. In the preoperative phase, the technician first spent 5-7 min to superimpose the virtual image of the head and the scalpel. The surgeon then took 2 min to identify the intended target position and entry point position on the tablet, which then dynamically displayed the superimposed image of the head, target position, entry point position, and scalpel (including the scalpel tip and scalpel orientation). Multiple experiments were successfully conducted on the phantom, along with six practical trials of clinical neurosurgical EVD. In the 2D-plane-superposition model, the optical measurement system (NDI Polaris Vicra) provided highly accurate visualization (2.01 ± 1.12 mm). In hospital-based clinical trials, the average technician preparation time was 6 min, while the surgeon required an average of 3.5 min to set the target and entry-point positions and accurately overlay the orientation with an NDI surgical stick. In the preparation phase, the average time required for the DICOM-formatted image processing and program import was 120 ± 30 min. The accuracy of the designed augmented reality optical surgical navigation system met clinical requirements, and can provide a visual and intuitive guide for neurosurgeons. The surgeon can use the tablet application to obtain real-time DICOM-formatted images of the patient, change the position of the surgical entry point, and instantly obtain an updated surgical path and surgical angle. The proposed design can be used as the basis for various augmented reality brain surgery navigation systems in the future.

Indexed as

augmented realityneurosurgerysurgical navigation

Identifiers

PMID36292263
PMCPMC9601392
OpenAlexW4296625667

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.