Evidence map›Paper›PMID 36292237›Full record

ArticleDiagnostics (Basel, Switzerland)2022

Low Arousal Threshold Estimation Predicts Failure of Mandibular Advancement Devices in Obstructive Sleep Apnea Syndrome.

Caterina Antonaglia, Gabriele Vidoni, Luca Contardo, Fabiola Giudici, Francesco Salton, Barbara Ruaro, Marco Confalonieri, Martina Caneva

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Caterina AntonagliaPulmonology Department, University Hospital of Cattinara, 34149 Trieste, Italy.
Gabriele VidoniDepartment of Medicine, Surgery and Health Sciences, School of Dentistry, University of Trieste, 34127 Trieste, Italy.
Luca ContardoDepartment of Medicine, Surgery and Health Sciences, School of Dentistry, University of Trieste, 34127 Trieste, Italy.
Fabiola GiudiciDepartment of Biostatistics and Epidemiology, Gustave Roussy, Paris-Saclay University, 91190 Gif-sur-Yvette, France.ORCID 0000-0002-4160-3479
Francesco SaltonPulmonology Department, University Hospital of Cattinara, 34149 Trieste, Italy.
Barbara RuaroPulmonology Department, University Hospital of Cattinara, 34149 Trieste, Italy.ORCID 0000-0001-8990-859X
Marco ConfalonieriPulmonology Department, University Hospital of Cattinara, 34149 Trieste, Italy.ORCID 0000-0002-4791-768X
Martina CanevaDepartment of Medicine, Surgery and Health Sciences, School of Dentistry, University of Trieste, 34127 Trieste, Italy.
University of Trieste · ITOspedale di Cattinara · ITUniversité Paris-Saclay · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: The treatment of choice for obstructive sleep apnea syndrome (OSAS) is continuous positive airway pressure (CPAP). However, CPAP is usually poorly tolerated and mandibular advancement devices (MADs) are an alternative innovative therapeutic approach. Uncertainty still remains as to the most suitable candidates for MAD. Herein, it is hypothesized that the presence of low arousal threshold (low ArTH) could be predictive of MAD treatment failure. Methods: A total of 32 consecutive patients, with OSAS of any severity, who preferred an alternate therapy to CPAP, were treated with a tailored MAD aimed at obtaining 50% of their maximal mandibular advancement. Treatment response after 6 months of therapy was defined as AHI < 5 events per hour or a reduction of AHI ≥ 50% from baseline. Low ArTH was predicted based on the following polysomnography features, as previously shown by Edwards et al.: an AHI of 82.5% and a hypopnea fraction of total respiratory events of >58.3%. Results: There were 25 (78.1%) responders (p-value < 0.01) at 6 months. Thirteen patients (40.6%) in the non-severe group reached AHI lower than 5 events per hour. MAD treatment significantly reduced the median AHI in all patients from a median value of 22.5 to 6.5 (74.7% of reduction, p-value < 0.001). The mandibular advancement device reduced AHI, whatever the disease severity. A significant higher reduction of Delta AHI, after 6 months of treatment, was found for patients without low ArTH. Conclusions: Low ArTH at baseline was associated with a poorer response to MAD treatment and a lower AHI reduction at 6 months. A non-invasive assessment of Low ArTH can be performed through the Edwards’ score, which could help to identify an endotype with a lower predicted response to oral appliances in a clinical setting.

Indexed as

low arousal threshold (low ArTH)mandibular advancement devices (MADs)obstructive sleep apnea syndrome (OSAS)

Identifiers

PMID36292237
PMCPMC9600433
OpenAlexW4306916579

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.