Evidence map›Paper›PMID 36292008›Full record

ArticleDiagnostics (Basel, Switzerland)2022

Intra- and Inter-Reader Variations in Lung Nodule Measurements: Influences of Nodule Size, Location, and Observers.

Hong Chen, Haozhe Huang, Jianye Zhang, Xuexue Wang, Mengyang Han, Chanjun Ding, Jinhong Wang

Abstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hong ChenDepartment of Medical Imaging, Shanghai Mental Health Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200030, China.ORCID 0000-0002-2168-9156
Haozhe HuangDepartment of Interventional Radiology, Fudan University Shanghai Cancer Center, 270 Dongan Road, Xuhui District, Shanghai 200032, China.ORCID 0000-0001-6765-5931
Jianye ZhangDepartment of Medical Imaging, Shanghai Mental Health Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200030, China.
Xuexue WangDepartment of Medical Imaging, Shanghai Mental Health Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200030, China.
Mengyang HanDepartment of Medical Imaging, Shanghai Mental Health Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200030, China.
Chanjun DingDepartment of Medical Imaging, Shanghai Mental Health Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200030, China.
Jinhong WangDepartment of Medical Imaging, Shanghai Mental Health Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200030, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

(1) Background: Accurate measurement of lung-nodule size is necessary, but whether a three-dimensional volume measurement is better or more reliable than the one-dimensional method is still unclear. This study aimed to investigate the intra- and inter-reader variations according to nodule type, size, three-dimensional volume measurements, and one-dimensional linear measurements. (2) Methods: This retrospective study included computed tomography (CT) examinations of lung nodules and volume measurements performed from October to December 2016. Two radiologists independently performed all measurements. Intra-class correlation coefficients (ICC) and Bland-Altman plots were used for analysis. (3) Results: The overall variability in the calculated volume was larger than when using the semiautomatic volume measurement. Nodules <6 mm tended to have larger variability than nodules ≥6 mm in both one-dimensional and calculated volume measurements. The isolated type showed smaller variability in both intra- and inter-reader comparisons. The juxta-vascular type showed the largest variability in both one-dimensional and calculated volume measurements. The variability was decreased when using the 3D volume semiautomated software. (4) Conclusions: The present study suggests that 3D semiautomatic volume measurements showed lower variability than the calculated volume measurement. Nodule size and location influence measurement variability. The intra- and inter-reader variabilities in nodule volume measurement were considerable.

Indexed as

chestcomputed tomographyimagingmeasurementpulmonary nodulesthree-dimensional

Identifiers

PMID36292008
PMCPMC9600531

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.