Evidence map›Paper›PMID 36290518›Full record

ArticleBioengineering (Basel, Switzerland)2022

3D Printed Skull Cap and Benchtop Fabricated Microwire-Based Microelectrode Array for Custom Rat Brain Recordings.

Dongyang Yi, Jeremiah P Hartner, Brian S Ung, Harrison L Zhu, Brendon O Watson, Lei Chen

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Dongyang YiDepartment of Mechanical Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA.ORCID 0000-0002-7994-0454
Jeremiah P HartnerDepartment of Psychiatry, University of Michigan, Ann Arbor, MI 48109, USA.
Brian S UngDepartment of Mechanical Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA.
Harrison L ZhuDepartment of Mechanical Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA.
Brendon O WatsonDepartment of Psychiatry, University of Michigan, Ann Arbor, MI 48109, USA.ORCID 0000-0002-9940-4579
Lei ChenDepartment of Mechanical Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA.ORCID 0000-0003-4042-9912

Funding

A universal and 3D-printed rat calvarium replacement system to enable for pan-cortical and sub-cortical recordings and optogeneticsR21MH120465 · NIMH · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI WATSON, BRENDON O · 2020 to 2020
$429k
NIH HHS R21 MH120465NIMH NIH HHS R21 MH120465
6 · The paper itself

Abstract

Microwire microelectrode arrays (MEAs) have been a popular low-cost tool for chronic electrophysiological recordings and are an inexpensive means to record the electrical dynamics crucial to brain function. However, both the fabrication and implantation procedures for multi-MEAs on a single rodent are time-consuming and the accuracy and quality are highly manual skill-dependent. To address the fabrication and implantation challenges for microwire MEAs, (1) a computer-aided designed and 3D printed skull cap for the pre-determined implantation locations of each MEA and (2) a benchtop fabrication approach for low-cost custom microwire MEAs were developed. A proof-of-concept design of a 32-channel 4-MEA (8-wire each) recording system was prototyped and tested through Sprague Dawley rat recordings. The skull cap design, based on the CT-scan of a single rat conforms well with multiple Sprague Dawley rats of various sizes, ages, and weight with a minimal bregma alignment error (A/P axis standard error of the mean = 0.25 mm, M/L axis standard error of the mean = 0.07 mm, n = 6). The prototyped 32-channel system was able to record the spiking activities over five months. The developed benchtop fabrication method and the 3D printed skull cap implantation platform would enable neuroscience groups to conduct in-house design, fabrication, and implantation of customizable microwire MEAs at a lower cost than the current commercial options and experience a shorter lead time for the design modifications and iterations.

Indexed as

3D printingcustom designmicrowire microelectrode arraymulti-region electrophysiological recordingnormal-behaving rat brain recordingskull cap

Identifiers

PMID36290518
PMCPMC9598465

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked