Evidence map›Paper›PMID 36289892›Full record

ReviewBiomedicines2022

Indirect Comparison of 10 kHz Spinal Cord Stimulation (SCS) versus Traditional Low-Frequency SCS for the Treatment of Painful Diabetic Neuropathy: A Systematic Review of Randomized Controlled Trials.

Bryan C Hoelzer, Deborah Edgar, Shiao-Ping Lu, Rod S Taylor

Open access · goldAbstract readReview
In one paragraph

Review in Biomedicines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
4.5field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 19 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Review
  4. Review
  5. Review
  6. Review
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Bryan C HoelzerMedical Director, Southwest Spine and Pain Center, Provo, UT 84059, USA.
Deborah EdgarCommexus Ltd., Dunblane FK15 0DF, UK.
Shiao-Ping LuLucid Consulting, Los Altos, CA 94024, USA.
Rod S TaylorMRC/CSO Social and Public Health Sciences Unit & Robertson Centre for Biostatistics, School of Health and Well Being, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow G12 8QQ, UK.
Lucid Technologies (United States) · USUniversity of Exeter · GB

Funding

Nevro Corp. N/A
6 · The paper itself

Abstract

Spinal cord stimulation (SCS) is increasingly used to treat painful diabetic neuropathy (PDN). At the time of a recent meta-analysis in this field, data were only available from randomized controlled trials (RCTs) of traditional low-frequency SCS (LF-SCS). However, outcomes from high-frequency 10 kHz SCS treatment are now available. Our study aimed to systematically review the contemporary evidence for SCS in patients with lower limb pain due to PDN and include an indirect comparison of the high- and low-frequency modalities. We searched the PubMed/CENTRAL databases up to 18 August 2022, for peer-reviewed RCTs of SCS that enrolled PDN patients with lower limb pain symptoms. The quality of the evidence was assessed with the Cochrane Risk of Bias tool. Using SCS treatment arm data from the RCTs, we indirectly compared the absolute treatment effect of 10 kHz SCS and LF-SCS. Results are presented in tables and forest plots. This systematic review was reported according to the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) 2020 guidelines. Three RCTs met our eligibility criteria, including the recent 10 kHz SCS RCT (N = 216, 90 implanted) and 2 others that examined LF-SCS (N = 36, 17 implanted; N = 60, 37 implanted). Our analysis of 6-month data found clinically meaningful pain relief with each SCS modality. However, significantly greater pain reduction was identified for 10 kHz SCS over LF-SCS: average pain reduction in the 10 kHz SCS cohort was 73.7% compared with 47.5% in the pooled LF-SCS group (p < 0.0001). In the permanent implant subset, the 50% pain reduction responder rate was 83.3% in the 10 kHz SCS cohort versus 63.0% in the pooled LF-SCS group (p = 0.0072). The overall risk of bias of each included RCT was deemed high, mainly due to the absence of patient blinding. Our analysis indicates that paresthesia-free 10 kHz SCS can provide superior pain relief and responder rate over LF-SCS for managing PDN patients refractory to conventional medical management.

Indexed as

10 kHz SCSdiabetesmeta-analysisneuropathic painpainful diabetic neuropathyperipheral neuropathyspinal cord stimulationsystematic review

Identifiers

PMID36289892
PMCPMC9599433
OpenAlexW4306836479

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.