ReviewBiomedicines2022
Indirect Comparison of 10 kHz Spinal Cord Stimulation (SCS) versus Traditional Low-Frequency SCS for the Treatment of Painful Diabetic Neuropathy: A Systematic Review of Randomized Controlled Trials.
Review in Biomedicines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it, 19 citations in OpenAlex.
- Methodological and statistical characteristics of meta-analyses on spinal cord stimulation for chronic pain: a systematic review.Regional anesthesia and pain medicine · 2025Pooled it
- Long-term efficacy of high-frequency (10 kHz) spinal cord stimulation for the treatment of painful diabetic neuropathy: 24-Month results of a randomized controlled trial.Diabetes research and clinical practice · 2023Trial
- Peripheral nerve-mediated glucose lowering: Mechanisms, translational strategies, and future perspectives.World journal of diabetes · 2026Review
- Neuromodulation of the Cardiac Autonomic Nervous System for Arrhythmia Treatment.Biomedicines · 2025Review
- Comparative Effectiveness of Different Frequencies of Spinal Cord Stimulation for the Treatment of Patients with Failed Back Surgery Syndrome: Systematic Review and Network Meta-Analysis.Journal of pain research · 2025Review
- Spinal Cord Stimulation Waveforms for the Treatment of Chronic Pain.Current pain and headache reports · 2024Review
- Treatment of Painful Diabetic Neuropathy with 10 kHz Spinal Cord Stimulation: Long-Term Improvements in Hemoglobin A1c, Weight, and Sleep Accompany Pain Relief for People with Type 2 Diabetes.Journal of pain research · 2024Article
- Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 2 countries.
Funding
Abstract
Spinal cord stimulation (SCS) is increasingly used to treat painful diabetic neuropathy (PDN). At the time of a recent meta-analysis in this field, data were only available from randomized controlled trials (RCTs) of traditional low-frequency SCS (LF-SCS). However, outcomes from high-frequency 10 kHz SCS treatment are now available. Our study aimed to systematically review the contemporary evidence for SCS in patients with lower limb pain due to PDN and include an indirect comparison of the high- and low-frequency modalities. We searched the PubMed/CENTRAL databases up to 18 August 2022, for peer-reviewed RCTs of SCS that enrolled PDN patients with lower limb pain symptoms. The quality of the evidence was assessed with the Cochrane Risk of Bias tool. Using SCS treatment arm data from the RCTs, we indirectly compared the absolute treatment effect of 10 kHz SCS and LF-SCS. Results are presented in tables and forest plots. This systematic review was reported according to the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) 2020 guidelines. Three RCTs met our eligibility criteria, including the recent 10 kHz SCS RCT (N = 216, 90 implanted) and 2 others that examined LF-SCS (N = 36, 17 implanted; N = 60, 37 implanted). Our analysis of 6-month data found clinically meaningful pain relief with each SCS modality. However, significantly greater pain reduction was identified for 10 kHz SCS over LF-SCS: average pain reduction in the 10 kHz SCS cohort was 73.7% compared with 47.5% in the pooled LF-SCS group (p < 0.0001). In the permanent implant subset, the 50% pain reduction responder rate was 83.3% in the 10 kHz SCS cohort versus 63.0% in the pooled LF-SCS group (p = 0.0072). The overall risk of bias of each included RCT was deemed high, mainly due to the absence of patient blinding. Our analysis indicates that paresthesia-free 10 kHz SCS can provide superior pain relief and responder rate over LF-SCS for managing PDN patients refractory to conventional medical management.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.