Evidence map›Paper›PMID 36287800›Full record

ArticleTomography (Ann Arbor, Mich.)2022

Comparing the Diagnostic Performance of ECG Gated versus Non-Gated CT Angiography in Ascending Aortic Dissection: A GRRAS Study.

Razvan G Budeanu, Christian Broemmer, Anamaria R Budeanu, Marian Pop

Open access · goldAbstract read
In one paragraph

Article in Tomography (Ann Arbor, Mich.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 2 pooled it
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 2 syntheses or guidelines pooled it, 7 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Article
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Razvan G BudeanuEmergency County Hospital Târgu Mureș, 540136 Targu Mures, Romania.ORCID 0000-0002-1259-7305
Christian BroemmerME1 Department, "George Emil Palade" University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540142 Targu Mures, Romania.
Anamaria R BudeanuEmergency County Hospital Târgu Mureș, 540136 Targu Mures, Romania.
Marian PopME1 Department, "George Emil Palade" University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540142 Targu Mures, Romania.ORCID 0000-0001-5324-9780
Spitalul Clinic Judetean de Urgenta Târgu Mureş · ROUniversitatea de Medicină, Farmacie, Științe și Tehnologie „George Emil Palade” din Târgu Mureș · RO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Rationale and Objective: Thoracic CT angiography (CTA) for ascending aortic dissection, a life-threatening emergency, is performed routinely without Electrocardiographic (ECG) gating, therefore allowing the apparition of a pulsation artefact. We aimed to evaluate and compare the diagnostic performance, the inter and intra-reporter agreement of ECG gated CTA and non-ECG gated CTA for detecting ascending aortic dissection, considering their training level. Our hypothesis is that ECG gated CTA has superior diagnostic accuracy for ascending aortic dissection compared to non-gated CTA. Materials and Methods: We collected data using 24 questions survey using clinically validated CT examinations. Sixty-six respondents (medical students, radiology residents, and consultants) blinded to the actual diagnosis independently evaluated the images pertaining to the presence of ascending aortic dissection. The reference standard was represented by clinical and imaging diagnosis. Inter-rater and inter-group concordance was evaluated; the agreement with reference tests was calculated and assessed as a function of reporters’ training level. Results: Reporters’ ascending aortic dissection assessment showed a better correlation with the reference standard in the ECG gated CTA. The inter-rater correlation was higher in the ECG gated CTA compared to non-ECG gated CTA. Observers’ confidence for diagnosing ascending aortic dissection was higher in the ECG gated CTA. Statistically significant differences (p < 0.05) were found between different training levels when assessing non-ECG gated examinations. Conclusions: ECG gated CTA shows a higher diagnostic performance for ascending aortic dissection than non-ECG gated CTA, regardless of the reporters’ training level.

Indexed as

Aortic DissectionComputed Tomography AngiographyAngiographyCardiac-Gated Imaging TechniquesElectrocardiographyHumansascending aortic dissectionCTAECG-gatedinter-rater reliabilityradiology

Identifiers

PMID36287800
PMCPMC9609484
OpenAlexW4298003773

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.