In one paragraph

Review in EFORT open reviews, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.6field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 14 citations in OpenAlex.

  1. Trial
  2. The Diagnosis, Treatment, and Aftercare of Ankle Fractures.Deutsches Arzteblatt international · 2026
    Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

F T SpindlerDepartment of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany.ORCID 0000-0003-2591-5728
V HerterichDepartment of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany.
B M HolzapfelDepartment of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany.
W BöckerDepartment of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany.
H PolzerDepartment of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany.ORCID 0000-0002-6713-4017
S F BaumbachDepartment of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany.ORCID 0000-0002-6287-6206
Ludwig-Maximilians-Universität München · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The aim was to conduct a systematic literature review and meta-anaylsis to analyze the diagnostic accuracy of the external rotation stress test (ERST) for syndesmotic injuries. Methods: The systematic review was conducted according to the PRISMA-P guidelines (Prospero ID: CRD42021282457). Four common databases were searched from inception to September 29, 2021. Eligible were any studies facilitating the ERST under fluoroscopy in a defined state of syndesmotic instability. Syndesmotic ligament-specific rupture must have been proven by MRI, arthroscopy, or controlled dissection (cadaver study). Two reviewers independently conducted each step of the systematic literature review. The risk of bias was assessed by the Quality Appraisal for Cadaveric Studies Score scale. The data analysis was performed qualitatively and quantitatively. Results: Eight studies were eligible for a qualitative analysis, and six studies were eligible for a quantitative analysis. All studies included were cadaver studies. The qualitative analysis comprised 94 specimens and revealed considerable heterogeneity. Six studies allowed for a quantitative analysis of the tibiofibular clear space (TFCS) and five studies for the medial clear space (MCS) during the ERST. The quantitative analysis of the TFCS revealed no significant differences between intact and any stage of syndesmotic injury. The MCS was able to differentiate between intact and 2-ligament- (Z = 2.04, P = 0.02), 3-ligament- (Z = 3.2, P = 0.001), and 3-ligament + deltoid ruptures (Z = 3.35, P < 0.001). Conclusion: The ERST is the only noninvasive test to assess syndesmotic instability and can be conducted bilaterally. The uninjured contralateral side can serve as a baseline reference. Based on the conducted quantitative analysis, the MCS seems to be able to differentiate between stable (intact/1-ligament) and unstable (2-ligament/3-ligament) lesions.

Indexed as

external rotation stress testsyndesmosissyndesmotic injury

Identifiers

PMID36287127
PMCPMC9619390
OpenAlexW4307429980

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.