Evidence map›Paper›PMID 36286619›Full record

ArticleJournal of applied clinical medical physics2023

Evaluation of the feasibility of cardiac gating for SBRT of ventricular tachycardia based on real-time ECG signal acquisition.

Cristiano Q M Reis, James L Robar

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
2.3field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 17 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Radiation therapy for ventricular arrhythmias.Journal of medical imaging and radiation oncology · 2024
    Review
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Cristiano Q M ReisDepartment of Radiation Oncology, Dalhousie University, Halifax, Nova Scotia, Canada.
James L RobarDepartment of Radiation Oncology, Dalhousie University, Halifax, Nova Scotia, Canada.
Dalhousie University · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo investigate the feasibility of cardiac synchronized gating in stereotactic body radiation therapy (SBRT) of ventricular tachycardia (VT) using a real-time electrocardiogram (ECG) signal acquisition. METHODS AND MATERIALS: Stability of beam characteristics during simulated ECG gating was examined by developing a microcontroller interface to a Varian Clinac iX linear accelerator allowing gating at frequencies and duty cycles relevant to cardiac rhythm. Delivery accuracy was evaluated by measuring dose linearity with an ionization chamber, and flatness and symmetry with a two-dimensional detector array, for different gating windows within typical human cardiac cycle periods. To establish a practical method of gating based on actual ECG signals, an AD8232 Heart Monitor board was used to acquire the ECG signal and synchronize the beam delivery. Real-time cardiac gated delivery measurements were performed for a single 10 × 10 cm RESULTS AND DISCUSSION: Dose per monitor unit (MU) values were found to be linear within most gating windows investigated with maximum differences relative to non-gated delivery of <2% for gating windows ≥200 ms and for >10 MUs. Beam profiles for both gated and non-gated modes were also found to agree with maximum differences of 0.5% relative to central axis dose for all sets of beam-on/beam-off combinations. Comparison of dose distributions for intensity-modulated SBRT plans between non-gating and cardiac gating modes provided a gamma passing rate of 97.2% for a 2% 2 mm tolerance.

conclusionsBeam output is stable with respect to linearity, flatness, and symmetry for gating windows within cardiac cycle periods. Agreement between dose distributions for VT-SBRT using IMRT in non-gated and cardiac cycle gated delivery modes shows that the proposed methodology is feasible. Technically, gating for delivery of SBRT for VT is possible with regard to beam stability.

Indexed as

RadiosurgeryRadiotherapy, Intensity-ModulatedTachycardia, VentricularElectrocardiographyFeasibility StudiesHumansRadiotherapy DosageRadiotherapy Planning, Computer-Assistedreal-time cardiac gatingSBRTventricular tachycardia

Identifiers

PMID36286619
PMCPMC9924123
OpenAlexW4307341689

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.