ArticleAnalytical methods : advancing methods and applications2022
Evaluation of propylene glycol methyl ether as a potential challenge agent for leak detection of liquid and headspace from closed system drug transfer devices using Fourier transform infrared spectroscopy.
Article in Analytical methods : advancing methods and applications, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
- An assessment of seven closed system transfer devices in accordance with the 2015 NIOSH vapor containment performance protocol.Journal of oncology pharmacy practice : official publication of the International Society of Oncology Pharmacy Practitioners · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
Abstract
Choosing an appropriate surrogate of hazardous drugs for use in testing Closed System Drug-Transfer Devices (CSTDs) is a challenging endeavor with many factors that must be considered. It was suggested that the compound propylene glycol methyl ether (PGME) may meet many of the criteria we considered important in a suitable surrogate. Criteria included sufficient volatility to evaporate from aqueous liquid leaks efficiently, a Henry's constant which produced sufficient vapor phase concentrations to make headspace leaks detectable, and suitability for detection using a low-cost detection system. We evaluated the measurement of vapors from solutions containing PGME released inside a closed chamber. We present data used to quantify limits of detection, limits of quantification, bias, precision, and accuracy of Fourier Transform Infrared Spectroscopy (FTIR) measurements of vapors from 2.5 M PGME solutions. The effects of ethanol as a component of the PGME solution were also evaluated. Liquid drops of PGME solutions and headspace vapors above PGME solutions were released to simulate leaks from CSTDs. Using a calibration apparatus, an instrumental limit of detection (LOD) of 0.25 ppmv and a limit of quantitation (LOQ) of 0.8 ppmv were determined for PGME vapor. A LOD of 1.1 μL and a LOQ of 3.5 μL were determined for liquid aliquots of 2.5 M PGME solution released in a closed chamber. Accurate quantitation of liquid leaks required complete evaporation of droplets. With the upper end of the useable quantitation range limited by slow evaporation of relatively large droplets and the lower end defined by the method LOQ, the method evaluated in this research had a narrow quantitative range for liquid droplets. Displacement of 45 mL of vial headspace containing PGME vapor is the largest amount expected when using the draft NIOSH testing protocol. Release of an unfiltered 45 mL headspace aliquot within the NIOSH chamber was calculated to produce a concentration of 0.8 ppmv based on the Henry's constant, which is right at the instrumental LOQ. Therefore, the sensitivity of the method was not adequate to determine leaks of PGME vapor from a headspace release through an air filtering CSTD when using the draft NIOSH testing protocols with an FTIR analyzer.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.