Evidence map›Paper›PMID 36285133›Full record

ArticleCyborg and bionic systems (Washington, D.C.)2021

Classification of Soft Tissue Sarcoma Specimens with Raman Spectroscopy as Smart Sensing Technology.

Liming Li, Vamiq M Mustahsan, Guangyu He, Felix B Tavernier, Gurtej Singh, Brendan F Boyce, Fazel Khan, Imin Kao

Open access · diamondAbstract read
In one paragraph

Article in Cyborg and bionic systems (Washington, D.C.), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
1.0field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 9 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Liming LiDepartment of Mechanical Engineering, Stony Brook University, NY, USA.ORCID https://orcid.org/0000-0002-0415-3421
Vamiq M MustahsanDepartment of Mechanical Engineering, Stony Brook University, NY, USA.ORCID https://orcid.org/0000-0003-4149-322X
Guangyu HeDepartment of Mechanical Engineering, Stony Brook University, NY, USA.ORCID https://orcid.org/0000-0002-2878-5108
Felix B TavernierDepartment of Pathology and Laboratory Medicine, Stony Brook University Hospital, Stony Brook, NY, USA.
Gurtej SinghDivision of Plastic Surgery, Department of Surgery, Stony Brook University Hospital, Stony Brook, NY, USA.ORCID https://orcid.org/0000-0003-3884-8376
Brendan F BoyceDepartment of Pathology and Laboratory Medicine, Stony Brook University Hospital, Stony Brook, NY, USA.
Fazel KhanDepartment of Orthopaedic Surgery, Stony Brook University Hospital, Stony Brook, NY, USA.
Imin KaoDepartment of Mechanical Engineering, Stony Brook University, NY, USA.ORCID https://orcid.org/0000-0003-1658-9166
Stony Brook University · USStony Brook University Hospital · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Intraoperative confirmation of negative resection margins is an essential component of soft tissue sarcoma surgery. Frozen section examination of samples from the resection bed after excision of sarcomas is the gold standard for intraoperative assessment of margin status. However, it takes time to complete histologic examination of these samples, and the technique does not provide real-time diagnosis in the operating room (OR), which delays completion of the operation. This paper presents a study and development of sensing technology using Raman spectroscopy that could be used for detection and classification of the tumor after resection with negative sarcoma margins in real time. We acquired Raman spectra from samples of sarcoma and surrounding benign muscle, fat, and dermis during surgery and developed (i) a quantitative method (QM) and (ii) a machine learning method (MLM) to assess the spectral patterns and determine if they could accurately identify these tissue types when compared to findings in adjacent H&E-stained frozen sections. High classification accuracy (>85%) was achieved with both methods, indicating that these four types of tissue can be identified using the analytical methodology. A hand-held Raman probe could be employed to further develop the methodology to obtain spectra in the OR to provide real-time in vivo capability for the assessment of sarcoma resection margin status.

Identifiers

PMID36285133
PMCPMC9494724
OpenAlexW4200082744

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.