Evidence map›Paper›PMID 36284661›Full record

ArticleInterventional radiology (Higashimatsuyama-shi (Japan)2020

Radiation Exposure of Interventional Radiologists during Computed Tomography Fluoroscopy-Guided Percutaneous Cryoablation.

Yuko Seki, Masaya Miyazaki, Yasuhiro Fukushima, Masashi Ando, Yoshito Tsushima

Open access · diamondAbstract read
In one paragraph

Article in Interventional radiology (Higashimatsuyama-shi (Japan), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Yuko SekiDepartment of Radiology, Gunma University Hospital, Japan.
Masaya MiyazakiDepartment of Applied Medical Imaging, Gunma University Graduate School of Medicine, Japan.
Yasuhiro FukushimaDivision of Clinical Radiology Service, Kyoto University Hospital, Japan.
Masashi AndoDepartment of Radiology, Gunma University Hospital, Japan.
Yoshito TsushimaDepartment of Diagnostic Radiology and Nuclear Medicine, Gunma University Graduate School of Medicine, Japan.
Gunma University · JPGunma University Hospital · JPKyoto University Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The principal aim of this study was to evaluate radiation exposure of interventionalists during computed tomography (CT) fluoroscopy-guided percutaneous cryoablation (PCA) using radiophotoluminescent glass dosimeters (RPLDs). The radioprotective effects of safety glasses and lead apron were also evaluated. Materials and Methods: Radiation exposure of interventionalists during 46 CT fluoroscopy-guided PCA procedures was evaluated. Entrance surface dose (ESD) was measured using RPLDs on multiple sites: five sites, representing eye lens exposure; five sites, representing body exposure; and four sites, representing skin exposure. The ESD values on multiple sites were compared between different PCA procedures (renal, liver, and bone). Results: The mean ESD on the X-ray-side hand exhibited the highest value (358.8 μGy). Regarding evaluation sites representing exposure to the eye lens, the highest ESD inside the radiation protective glasses was detected on the X-ray-side cheek (167.1 μGy). Most ESD values among multiple sites (10/14) were linearly correlated with CT fluoroscopy time. Among them, the ESD values measured during renal and liver PCA were relatively higher than those measured during bone PCA, especially on the chest area outside the lead apron, and on the X-ray tube-side elbow and hand during renal and bone PCA. Radioprotective effects of safety glasses and lead apron ranged from 44.6 to 50.6% and from 30.2 to 79.6%, respectively, on each evaluation site. Conclusion: The site with the highest radiation exposure on interventionalists during CT fluoroscopy-guided PCA was the X-ray tube-side hand. Radiation exposure of interventionalists was at acceptable levels and consistent with the recommended dose limits.

Indexed as

Computed tomography fluoroscopyCryoablationRadiation exposure

Identifiers

PMID36284661
PMCPMC9550382
OpenAlexW3024954656

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.