Evidence map›Paper›PMID 36281510›Full record

ArticleAnnals of laboratory medicine2023

Performance Evaluation of the DxC 700 AU Chemistry Analyzer in Hemoglobin A1c Measurement

Yu Jeong Choi, Hyein Kang, Chan-Ik Cho, John Hoon Rim, Sang-Guk Lee, Jong-Baeck Lim

Abstract read
In one paragraph

Article in Annals of laboratory medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yu Jeong ChoiDepartment of Laboratory Medicine, Yonsei University College of Medicine, Seoul, Korea.ORCID 0000-0002-5151-6926
Hyein KangDepartment of Laboratory Medicine, Yonsei University College of Medicine, Seoul, Korea.ORCID 0000-0003-0789-8223
Chan-Ik ChoKorea Disease Control and Prevention Agency, Osong Health Technology Administration Complex, Cheongju, Korea.ORCID 0000-0002-5378-6794
John Hoon RimDepartment of Laboratory Medicine, Yonsei University College of Medicine, Seoul, Korea.ORCID 0000-0001-6825-8479
Sang-Guk LeeDepartment of Laboratory Medicine, Yonsei University College of Medicine, Seoul, Korea.ORCID 0000-0003-3862-3660
Jong-Baeck LimDepartment of Laboratory Medicine, Yonsei University College of Medicine, Seoul, Korea.ORCID 0000-0003-0419-0422

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Accurate measurement of glycated hemoglobin (HbA1c) is crucial for a diabetes diagnosis and subsequent patient management. The detection method and presence of variant Hb can interfere with HbA1c measurements. We evaluated the HbA1c-measuring performance of the DxC 700 AU (Beckman Coulter, Brea, CA, USA) immunoassay-based device in comparison with another immunoassay device and the reference method. Methods: A total of 120 normal and 14 variant Hb samples were analyzed using the Cobas c 513 (Roche Diagnostics, Mannheim, Germany) and DxC 700 AU analyzers. Variant Hb samples were also analyzed using the reference method, along with 20 normal samples. The accuracy, precision, linearity, and carryover were determined. Results: DxC 700 AU results strongly correlated with those of Cobas c 513 and exhibited accuracy in comparison with the reference method. The within-run, between-run, between-day, and total imprecision (%CV) values for the low- and high-concentration control materials were below 2%. The results of DxC 700 AU were linear over a wide HbA1c range (3.39%-18.30%). Although DxC 700 AU performed well in the presence of variant Hb, the HbA1c concentration was underestimated in the presence of fetal Hb. The possibility of interference from a high HbH proportion could not be ruled out. Conclusions: The overall analytical performance of DxC 700 AU was acceptable. The device is accurate, precise, and linear over a wide HbA1c concentration range. Although DxC 700 AU results highly correlated with those of Cobas c 513, caution should be exercised in cases of high HbF and HbH concentrations.

Indexed as

Hematologic TestsChromatography, High Pressure LiquidGlycated HemoglobinHumansImmunoassayGlycated HemoglobinFetal hemoglobinHemoglobin A1cVariant hemoglobin

Identifiers

PMID36281510
PMCPMC9618898

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.