Evidence map›Paper›PMID 36274797›Full record

ArticleIndian journal of anaesthesia2022

Optimal positioning of right internal jugular venous catheter: A randomised study comparing modified Peres' height formula and distance between insertion point and right third intercostal space.

Swati Chopra, Neeru Luthra, Suneet Kathuria, Kavita Saggar, Shikha Gupta, Tanveer Singh

Open access · diamondAbstract read
In one paragraph

Article in Indian journal of anaesthesia, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Risk of bias in published randomised controlled trials.Indian journal of anaesthesia · 2023
    Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 2 countries.

Swati ChopraDepartment of Anaesthesiology, Dayanand Medical College and Hospital, Ludhiana, Punjab, India.
Neeru LuthraDepartment of Anaesthesiology, Dayanand Medical College and Hospital, Ludhiana, Punjab, India.
Suneet KathuriaDepartment of Anaesthesiology, Dayanand Medical College and Hospital, Ludhiana, Punjab, India.
Kavita SaggarDepartment of Radiodiagnosis, Dayanand Medical College and Hospital, Ludhiana, Punjab, India.
Shikha GuptaDepartment of Anaesthesiology, Dayanand Medical College and Hospital, Ludhiana, Punjab, India.
Tanveer SinghDepartment of Anaesthesiology, Dayanand Medical College and Hospital, Ludhiana, Punjab, India.
Dayanand Medical College & Hospital · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Aims: The position of the tip of the central venous catheter (CVC) is important to minimise complications. The aim of our study was to compare modified Peres' height formula and landmark method using distance between puncture site and right third intercostal space (PS-RTICS) and to develop a reliable formula for correct positioning of tip of the CVC. Methods: This prospective, randomised study was conducted on 400 patients of either gender, of age 18 years and older, scheduled to undergo right internal jugular venous cannulation. Depending on the technique used for deciding the length of CVC to be inserted, the patients were randomly allocated into two groups: Group A, using modified Peres' height formula, that is, height of patient (cm)/10-2 and Group B, using distance between PS-RTICS and subtracting one from it, that is (PS-RTICS)-1. The carina was taken as the landmark for optimum insertion of CVC, which was confirmed on postprocedure chest X-ray. Data so obtained were tabulated and analysed. P<.05 was considered statistically significant for correlation and regression coefficients. Results: In group A, the mean length of catheter inserted was 15.18 ± 0.73 cm and the catheter tip was found to be 2.41 ± 0.85 cm distal to carina (P =0.001). Over-insertion was found in 98.45% patients in group A. In group B, the mean length of catheter inserted was 14.12 ± 0.85 cm and the catheter tip was found to be 0.20 ± 1.18 cm distal to carina. Conclusion: Though both landmark and modified Peres' height formula has low accuracy, landmark technique is superior in predicting correct depth of right internal jugular venous cannulation catheter.

Indexed as

Central venous catheterisationjugular veinsuperior vena cava

Identifiers

PMID36274797
PMCPMC9580582
OpenAlexW4292566014

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.