Evidence map›Paper›PMID 36273400›Full record

ArticleMedical physics2023

Hyperia: A novel methodology of developing anthropomorphic breast phantoms for X-ray imaging modalities - Part I: Concept and initial findings.

Lynda Ikejimba, Asma Farooqui, Peymon Ghazi

Abstract read
In one paragraph

Article in Medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Lynda IkejimbaMALCOVA LLC, Baltimore, Maryland, USA.
Asma FarooquiMALCOVA LLC, Baltimore, Maryland, USA.
Peymon GhaziMALCOVA LLC, Baltimore, Maryland, USA.

Funding

DEVELOPMENT OF PATIENT-DERIVED ANTHROPOMORPHIC BREAST PHANTOMS FOR AUTOMATED OBJECTIVE ASSESSMENT OF BREAST X-RAY IMAGING SYSTEMS75N91020C00055 · NCI · MALCOVA LLC · PI GHAZI, PEYMON · 2020 to 2020
$400k
NCI NIH HHS 75N91020C00055NIH HHS 75N91020C00055
6 · The paper itself

Abstract

purposeTo introduce a novel methodology for developing anthropomorphic breast phantoms for use in X-ray-based imaging modalities.

methods"Hyperization" is a quasi-stippling mapping operation in which regions of varying grayscale values in a 2D image are transformed into regions of varying holes on a surface. The holes can be cut or engraved on the sheet of paper using a high-resolution laser cutter/engraver. In hyperization, the main parameters are the size and the distance between the holes. Here, we introduce the concept and chronicle the development and characterization of a proof-of-concept prototype. In this study, we hypothesized that a resulting "Hyperia" phantom would be a realistic representative of a patient's breast tissue: it would exhibit similar X-ray properties and show textural complexities. We used breast computed tomography (bCT) images of real patients as the input models. Using a previously developed segmentation method, the input CT images were segmented into different tissue classes (skin, adipose, and fibroglandular). The segmented images were then "Hyperized". A series of Monte Carlo simulations were conducted to find the optimal hyperization parameters. Different laser cutter/engraver systems and substrate materials were explored to find a viable option for developing an entire Hyperia breast phantom. The resulting phantom was imaged on a prototype breast CT system, and the resulting images were evaluated based on physical properties and similarity to the original patient data.

resultsThe simulation results indicate close similarities - both in the distribution of different tissue types and the resulting CT numbers - between the patient bCT image and the bCT of the Hyperia phantom, regardless of the breast size and density: the Pearson correlation coefficient (ρ) ranged from 0.88 in a BIRADS A breast to 0.94 in BIRADS C and D breasts (ρ of 1.00 suggests perfect structural similarity), and the volumetric mean squared error ranged from 0.0033 (in BIRADS D breast) to 0.0059 (in BIRADS A), suggesting good agreement between the resulting CT numbers. For fabricating the slices, the office paper was found to be an optimal substrate material, with the Hyperization parameters of (α, β) = (0.200 mm, 0.400 mm).

conclusionA novel phantom can be used for X-ray-based breast cancer imaging systems. The main advantage is that only one material is used for creating a contrast between different tissue types in an image.

Indexed as

BreastTomography, X-Ray ComputedComputer SimulationHumansPhantoms, ImagingX-Raysanthropomorphic phantombreast phantomequivalent materialtissue

Identifiers

PMID36273400
PMCPMC9931645

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.