ArticleMedical physics2023
Accurate and efficient measurement of channelized Hotelling observer-based low-contrast detectability on the ACR CT accreditation phantom.
Article in Medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 11 citations in OpenAlex.
- Institutional CT dose reduction: A retrospective evaluation of dose indices from 2015-2024.Journal of applied clinical medical physics · 2026Article
- FMDNet: Spatial-frequency feature routing for low-dose CT denoising.Journal of applied clinical medical physics · 2026Article
- Characterization of Breast Microcalcifications Using Dual-Energy CBCT: Impact of Detector Configuration on Imaging Performance-A Simulation Study.Sensors (Basel, Switzerland) · 2025Article
- Patient-specific Channelized Hotelling observer to estimate lesion detectability in CT.Proceedings of SPIE--the International Society for Optical Engineering · 2025Article
- Low-contrast detectability of photon-counting-detector CT at different scan modes and image types in comparison with energy-integrating-detector CT.Journal of medical imaging (Bellingham, Wash.) · 2024Article
- 3D printed phantom with 12 000 submillimeter lesions to improve efficiency in CT detectability assessment.Medical physics · 2024Article
- Channelized hotelling observer-based low-contrast detectability on the ACR CT accreditation phantom: Part II. Repeatability study.Medical physics · 2024Article
- Automated Web-based Software for CT Quality Control Testing of Low-contrast Detectability using Model Observers.Proceedings of SPIE--the International Society for Optical Engineering · 2024Article
- Evaluation of Low-contrast Detectability of Photon-Counting-Detector CT Using Channelized Hotelling Observer and an ACR Accreditation Phantom.Proceedings of SPIE--the International Society for Optical Engineering · 2023Article
- Efficient Evaluation of Low-contrast Detectability of Deep-CNN-based CT Reconstruction Using Channelized Hotelling Observer on the ACR Accreditation Phantom.Proceedings of SPIE--the International Society for Optical EngineeringArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
Abstract
backgroundCurrent CT quality control (QC) for low-contrast detectability relies on visual inspection and measurement of contrast-to-noise ratio (CNR). However, CNR numbers become unreliable when it comes to nonlinear methods, such as iterative reconstruction (IR) and deep-learning-based techniques. Image quality metrics using channelized Hotelling observer (CHO) have been validated to be well correlated with human observer performance on phantom-based and patient-based tasks, but it has not been widely used in routine CT QC mainly because the CHO calculation typically requires a large number of repeated scans in order to provide accurate and precise estimate of index of detectability (d'). PURPOSE: The main goal of this work is to optimize channel filters and other CHO parameters and accurately estimate the low-contrast detectability with minimum number of repeated scans for the widely used American College of Radiology (ACR) CT accreditation phantom so that it can become practically feasible for routine CT QC tests.
methodsTo provide a converged d' value, an ACR phantom was repeatedly scanned 100 times at three dose levels (24, 12, and 6 mGy). Images were reconstructed with two kernels (FBP Br44 and IR Br44-3). d' as a function of number of repeated scans was determined for different number of background regions of interest (ROIs), different number of low-contrast objects, different number of slices per each object, and different channel filter options. A reference d' was established using the optimized CHO setting, and the bias of d' was quantified using the d' calculated from all 100 repeated scans. The variation of d' at each condition was estimated using a resampling method combining random subsampling among 100 repeated scans and bootstrapping of the ensembles of signal and background ROIs.
resultsOptimized parameters in CHO calculation were determined: two background ROIs per object, four objects per low-contrast object size, nine non-overlapping slices per object, and a 4-channel Gabor filter. The bias and uncertainty were estimated at different numbers of repeated scans using these parameters. When only one single scan was used in the CHO calculation, the bias of d' was below 6.2% and the uncertainty 15.6-19.6% for the 6, 5, and 4 mm objects, while with three repeated scans the bias was below 2.0% and uncertainty 8.7-10.9% for the three object sizes.
conclusionWith optimized parameter settings in CHO, efficient and accurate measurement of low-contrast detectability on the commonly used ACR phantom becomes feasible, which could potentially lead to adoption of CHO-based low-contrast evaluation in routine QC tests.