Accurate and efficient measurement of channelized Hotelling observer-based low-contrast detectability on the ACR CT accreditation phantom.

Mingdong Fan, Theodore Thayib, Cynthia McCollough, Lifeng Yu

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
0.9field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. FMDNet: Spatial-frequency feature routing for low-dose CT denoising.Journal of applied clinical medical physics · 2026
    Article
  3. Article
  4. Patient-specific Channelized Hotelling observer to estimate lesion detectability in CT.Proceedings of SPIE--the International Society for Optical Engineering · 2025
    Article
  5. Article
  6. Article
  7. Article
  8. Automated Web-based Software for CT Quality Control Testing of Low-contrast Detectability using Model Observers.Proceedings of SPIE--the International Society for Optical Engineering · 2024
    Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Mingdong FanDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Theodore ThayibDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Cynthia McColloughDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Lifeng YuDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Mayo Clinic · US

Funding

Trade-offs in human observer performance, image quality metrics, and patient doseR01EB017095 · NIBIB · MAYO CLINIC ROCHESTER · PI Hao Gong, Cynthia H McCollough · 2012 to 2026
$7.0M
Dissemination of a Software Platform for Efficient CT Radiation Dose Optimization and Diagnostic Performance AssessmentU24EB028936 · NIBIB · MAYO CLINIC ROCHESTER · PI YU, LIFENG · 2019 to 2023
$1.6M
NIBIB NIH HHS R01 EB017095NIBIB NIH HHS U24 EB028936NIH HHS R01EB017095NIH HHS U24EB028936
6 · The paper itself

Abstract

backgroundCurrent CT quality control (QC) for low-contrast detectability relies on visual inspection and measurement of contrast-to-noise ratio (CNR). However, CNR numbers become unreliable when it comes to nonlinear methods, such as iterative reconstruction (IR) and deep-learning-based techniques. Image quality metrics using channelized Hotelling observer (CHO) have been validated to be well correlated with human observer performance on phantom-based and patient-based tasks, but it has not been widely used in routine CT QC mainly because the CHO calculation typically requires a large number of repeated scans in order to provide accurate and precise estimate of index of detectability (d'). PURPOSE: The main goal of this work is to optimize channel filters and other CHO parameters and accurately estimate the low-contrast detectability with minimum number of repeated scans for the widely used American College of Radiology (ACR) CT accreditation phantom so that it can become practically feasible for routine CT QC tests.

methodsTo provide a converged d' value, an ACR phantom was repeatedly scanned 100 times at three dose levels (24, 12, and 6 mGy). Images were reconstructed with two kernels (FBP Br44 and IR Br44-3). d' as a function of number of repeated scans was determined for different number of background regions of interest (ROIs), different number of low-contrast objects, different number of slices per each object, and different channel filter options. A reference d' was established using the optimized CHO setting, and the bias of d' was quantified using the d' calculated from all 100 repeated scans. The variation of d' at each condition was estimated using a resampling method combining random subsampling among 100 repeated scans and bootstrapping of the ensembles of signal and background ROIs.

resultsOptimized parameters in CHO calculation were determined: two background ROIs per object, four objects per low-contrast object size, nine non-overlapping slices per object, and a 4-channel Gabor filter. The bias and uncertainty were estimated at different numbers of repeated scans using these parameters. When only one single scan was used in the CHO calculation, the bias of d' was below 6.2% and the uncertainty 15.6-19.6% for the 6, 5, and 4 mm objects, while with three repeated scans the bias was below 2.0% and uncertainty 8.7-10.9% for the three object sizes.

conclusionWith optimized parameter settings in CHO, efficient and accurate measurement of low-contrast detectability on the commonly used ACR phantom becomes feasible, which could potentially lead to adoption of CHO-based low-contrast evaluation in routine QC tests.

Indexed as

AccreditationTomography, X-Ray ComputedAlgorithmsHumansImage Processing, Computer-AssistedPhantoms, ImagingRadiation DosageRadiographic Image Interpretation, Computer-AssistedUncertaintycomputed tomographyimage qualitymodel observerquality control

Identifiers

PMID36273393
PMCPMC9931649
OpenAlexW4307115373

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.