Trial reportThe Lancet. Neurology2022
Intraoperative electrocorticography using high-frequency oscillations or spikes to tailor epilepsy surgery in the Netherlands (the HFO trial): a randomised, single-blind, adaptive non-inferiority trial.
Trial report in The Lancet. Neurology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02207673 (Intra-operative Detection and Localisation of High Frequency Oscillations in the ECoG to Guide Epilepsy Surgery), which is not on this map. Cited by 55 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Intra-operative Detection and Localisation of High Frequency Oscillations in the ECoG to Guide Epilepsy Surgery
Who cites it
55 citing papers in PubMed, 2 syntheses or guidelines pooled it, 100 citations in OpenAlex.
- Seizure Outcome After Intraoperative Electrocorticography-Tailored Epilepsy Surgery: A Systematic Review and Meta-Analysis.Neurology · 2024Pooled it
- Prognostic Value of Complete Resection of the High-Frequency Oscillation Area in Intracranial EEG: A Systematic Review and Meta-Analysis.Neurology · 2024Pooled it
- Influences of electrode density on intracranial seizure localisation: a single-blinded randomised crossover study.EBioMedicine · 2025Trial
- Internal and external validation of comprehensive high-frequency activity biomarkers for epilepsy surgery.Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology · 2026Article
- Article
- The Influence of Recording Duration and Vigilance State on High-Frequency Oscillation Characterization in Epilepsy.Neurology · 2026Article
- Inroads into epilepsy through high-frequency oscillations: Achievements and benchmark areas for improvement.Epilepsia · 2026Review
- Article
- Multimodal integration of magnetic resonance imaging and intracranial electroencephalographic abnormalities in temporal lobe epilepsy surgery.Epilepsia · 2026Article
- Toward Unified Biomarkers for Focal Epilepsy.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2026Article
- Multi-montage visualization of interictal epileptic events in high-density intraoperative electrocorticography.Clinical neurophysiology practice · 2026Article
- Impact of Anesthesia With Propofol on Epileptic Discharges Recorded by Stereo-Electroencephalography in Pediatric Epilepsy Surgery.CNS neuroscience & therapeutics · 2026Article
- Internal and External Validation of Comprehensive High-Frequency Activity Biomarkers for Epilepsy Surgery.medRxiv : the preprint server for health sciences · 2025Article
- Mapping epileptogenic brain using a unified spatial-temporal-spectral source imaging framework.Proceedings of the National Academy of Sciences of the United States of America · 2025Article
- Self-supervised data-driven approach defines pathological high-frequency oscillations in epilepsy.Epilepsia · 2025Article
- PyHFO 2.0: an open-source platform for deep learning-based clinical high-frequency oscillations analysis.Journal of neural engineering · 2025Article
- Intraoperative Techniques for Language Mapping in Brain Surgery: A Comparison Between Direct Electrical Stimulation (DES) and Electrocorticography (ECoG).Brain and behavior · 2025Review
- Localization of the Epileptogenic Zone Using Neural Spatial Volatility in Epilepsy Surgery.Neurology · 2025Observational
- AI-based localization of the epileptogenic zone using intracranial EEG.Epilepsia open · 2025Review
- Implementing intraoperative high-density electrocorticography during epilepsy surgery.Epilepsia · 2025Article
Corrections and comments
- Commented on by
Authors and funding
20 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIntraoperative electrocorticography is used to tailor epilepsy surgery by analysing interictal spikes or spike patterns that can delineate epileptogenic tissue. High-frequency oscillations (HFOs) on intraoperative electrocorticography have been proposed as a new biomarker of epileptogenic tissue, with higher specificity than spikes. We prospectively tested the non-inferiority of HFO-guided tailoring of epilepsy surgery to spike-guided tailoring on seizure freedom at 1 year.
methodsThe HFO trial was a randomised, single-blind, adaptive non-inferiority trial at an epilepsy surgery centre (UMC Utrecht) in the Netherlands. We recruited children and adults (no age limits) who had been referred for intraoperative electrocorticography-tailored epilepsy surgery. Participants were randomly allocated (1:1) to either HFO-guided or spike-guided tailoring, using an online randomisation scheme with permuted blocks generated by an independent data manager, stratified by epilepsy type. Treatment allocation was masked to participants and clinicians who documented seizure outcome, but not to the study team or neurosurgeon. Ictiform spike patterns were always considered in surgical decision making. The primary endpoint was seizure outcome after 1 year (dichotomised as seizure freedom [defined as Engel 1A-B] vs seizure recurrence [Engel 1C-4]). We predefined a non-inferiority margin of 10% risk difference. Analysis was by intention to treat, with prespecified subgroup analyses by epilepsy type and for confounders. This completed trial is registered with the Dutch Trial Register, Toetsingonline ABR.NL44527.041.13, and ClinicalTrials.gov, NCT02207673.
findingsBetween Oct 10, 2014, and Jan 31, 2020, 78 individuals were enrolled to the study and randomly assigned (39 to HFO-guided tailoring and 39 to spike-guided tailoring). There was no loss to follow-up. Seizure freedom at 1 year occurred in 26 (67%) of 39 participants in the HFO-guided group and 35 (90%) of 39 in the spike-guided group (risk difference -23·5%, 90% CI -39·1 to -7·9; for the 48 patients with temporal lobe epilepsy, the risk difference was -25·5%, -45·1 to -6·0, and for the 30 patients with extratemporal lobe epilepsy it was -20·3%, -46·0 to 5·4). Pathology associated with poor prognosis was identified as a confounding factor, with an adjusted risk difference of -7·9% (90% CI -20·7 to 4·9; adjusted risk difference -12·5%, -31·0 to 5·9, for temporal lobe epilepsy and 5·8%, -7·7 to 19·5, for extratemporal lobe epilepsy). We recorded eight serious adverse events (five in the HFO-guided group and three in the spike-guided group) requiring hospitalisation. No patients died.
interpretationHFO-guided tailoring of epilepsy surgery was not non-inferior to spike-guided tailoring on intraoperative electrocorticography. After adjustment for confounders, HFOs show non-inferiority in extratemporal lobe epilepsy. This trial challenges the clinical value of HFOs as an epilepsy biomarker, especially in temporal lobe epilepsy. Further research is needed to establish whether HFO-guided intraoperative electrocorticography holds promise in extratemporal lobe epilepsy.
fundingUMCU Alexandre Suerman, EpilepsieNL, RMI Talent Fellowship, European Research Council, and MING Fund.