Evidence map›Paper›PMID 36266416›Full record

ArticleScientific reports2022

Trainable joint bilateral filters for enhanced prediction stability in low-dose CT.

Fabian Wagner, Mareike Thies, Felix Denzinger, Mingxuan Gu, Mayank Patwari, Stefan Ploner, Noah Maul, Laura Pfaff, Yixing Huang, Andreas Maier

Abstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Accelerated EPR imaging using deep learning denoising.Magnetic resonance in medicine · 2025
    Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Fabian WagnerPattern Recognition Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91058, Erlangen, Germany. fabian.wagner@fau.de.
Mareike ThiesPattern Recognition Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91058, Erlangen, Germany.
Felix DenzingerPattern Recognition Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91058, Erlangen, Germany.
Mingxuan GuPattern Recognition Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91058, Erlangen, Germany.
Mayank PatwariPattern Recognition Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91058, Erlangen, Germany.
Stefan PlonerPattern Recognition Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91058, Erlangen, Germany.
Noah MaulPattern Recognition Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91058, Erlangen, Germany.
Laura PfaffPattern Recognition Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91058, Erlangen, Germany.
Yixing HuangPattern Recognition Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91058, Erlangen, Germany.
Andreas MaierPattern Recognition Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91058, Erlangen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Low-dose computed tomography (CT) denoising algorithms aim to enable reduced patient dose in routine CT acquisitions while maintaining high image quality. Recently, deep learning (DL)-based methods were introduced, outperforming conventional denoising algorithms on this task due to their high model capacity. However, for the transition of DL-based denoising to clinical practice, these data-driven approaches must generalize robustly beyond the seen training data. We, therefore, propose a hybrid denoising approach consisting of a set of trainable joint bilateral filters (JBFs) combined with a convolutional DL-based denoising network to predict the guidance image. Our proposed denoising pipeline combines the high model capacity enabled by DL-based feature extraction with the reliability of the conventional JBF. The pipeline's ability to generalize is demonstrated by training on abdomen CT scans without metal implants and testing on abdomen scans with metal implants as well as on head CT data. When embedding RED-CNN/QAE, two well-established DL-based denoisers in our pipeline, the denoising performance is improved by 10%/82% (RMSE) and 3%/81% (PSNR) in regions containing metal and by 6%/78% (RMSE) and 2%/4% (PSNR) on head CT data, compared to the respective vanilla model. Concluding, the proposed trainable JBFs limit the error bound of deep neural networks to facilitate the applicability of DL-based denoisers in low-dose CT pipelines.

Indexed as

Image Processing, Computer-AssistedTomography, X-Ray ComputedAlgorithmsHumansNeural Networks, ComputerReproducibility of ResultsSignal-To-Noise Ratio

Identifiers

PMID36266416
PMCPMC9585057

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.