ArticleIndian journal of clinical biochemistry : IJCB2022
Determination of Manganese in Serum Using GFAAS: Serum Reference Values for Manganese in the Adolescent Girls of the DERVAN Cohort.
Article in Indian journal of clinical biochemistry : IJCB, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 4 citations in OpenAlex.
- Consequences of Disturbing Manganese Homeostasis.International journal of molecular sciences · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Current proposed method allows for the determination of manganese in serum sample using aqueous standard calibration technique on Graphite Furnace atomic absorption spectrophotometer (GFAAS) using deuterium background correction. This method involves determination of manganese from digested serum samples without the use of matrix modifier. Pyrolysis and atomization temperatures are 1200 °C and 2200 °C respectively. The limit of detection (LoD) and limit of quantitation (LoQ) of the method are 0.0097 ng/ml (0.18 nmol/l) and 0.032 ng/ml (0.58 nmol/l) respectively. Validation of the method was carried out using seronorm trace element level-1 serum standard with excellent agreement between measured value and certified value. Accuracy was demonstrated by the spike and recovery study with analytical recovery between 98.8 and 100.6% in serum. The serum reference value for manganese in adolescent girls of rural Konkan region of India range from 4.7 to 215 nmol/l.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.