Evidence map›Paper›PMID 36262044›Full record

ArticleBiophysical journal2022

Characterization of the pace-and-drive capacity of the human sinoatrial node: A 3D in silico study.

Antoine Amsaleg, Jorge Sánchez, Ralf Mikut, Axel Loewe

Open access · hybridAbstract read
In one paragraph

Article in Biophysical journal, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.3field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Stress-induced pacemaker desynchronization in the sinoatrial node.Frontiers in cardiovascular medicine · 2026
    Article
  4. Article
  5. Computational modelling of biological systems now and then: revisiting tools and visions from the beginning of the century.Philosophical transactions. Series A, Mathematical, physical, and engineering sciences · 2025
    Review
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Antoine AmsalegInstitute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany.
Jorge SánchezInstitute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany.
Ralf MikutInstitute for Automation and Applied Informatics, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany.
Axel LoeweInstitute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany. Electronic address: publications@ibt.kit.edu.
Karlsruhe Institute of Technology · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The sinoatrial node (SAN) is a complex structure that spontaneously depolarizes rhythmically ("pacing") and excites the surrounding non-automatic cardiac cells ("drive") to initiate each heart beat. However, the mechanisms by which the SAN cells can activate the large and hyperpolarized surrounding cardiac tissue are incompletely understood. Experimental studies demonstrated the presence of an insulating border that separates the SAN from the hyperpolarizing influence of the surrounding myocardium, except at a discrete number of sinoatrial exit pathways (SEPs). We propose a highly detailed 3D model of the human SAN, including 3D SEPs to study the requirements for successful electrical activation of the primary pacemaking structure of the human heart. A total of 788 simulations investigate the ability of the SAN to pace and drive with different heterogeneous characteristics of the nodal tissue (gradient and mosaic models) and myocyte orientation. A sigmoidal distribution of the tissue conductivity combined with a mosaic model of SAN and atrial cells in the SEP was able to drive the right atrium (RA) at varying rates induced by gradual If block. Additionally, we investigated the influence of the SEPs by varying their number, length, and width. SEPs created a transition zone of transmembrane voltage and ionic currents to enable successful pace and drive. Unsuccessful simulations showed a hyperpolarized transmembrane voltage (-66 mV), which blocked the L-type channels and attenuated the sodium-calcium exchanger. The fiber direction influenced the SEPs that preferentially activated the crista terminalis (CT). The location of the leading pacemaker site (LPS) shifted toward the SEP-free areas. LPSs were located closer to the SEP-free areas (3.46 ± 1.42 mm), where the hyperpolarizing influence of the CT was reduced, compared with a larger distance from the LPS to the areas where SEPs were located (7.17± 0.98 mm). This study identified the geometrical and electrophysiological aspects of the 3D SAN-SEP-CT structure required for successful pace and drive in silico.

Indexed as

LipopolysaccharidesSinoatrial NodeAction PotentialsHeart AtriaHumansSodium-Calcium ExchangerLipopolysaccharidesSodium-Calcium Exchanger

Identifiers

PMID36262044
PMCPMC9703096
OpenAlexW4306756865

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.