Evidence map›Paper›PMID 36261754›Full record

ArticleRadiological physics and technology2022

Simple quality assurance based on filtered back projection for geometrical/irradiation accuracy in single-isocenter multiple-target stereotactic radiotherapy.

Naoki Hayashi, Shun Kurata, Yasunori Saito, Shuta Ogawa, Keisuke Yasui

Abstract read
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.1field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Naoki HayashiSchool of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan. hayashi@fujita-hu.ac.jp.ORCID http://orcid.org/0000-0002-1720-3651
Shun KurataSchool of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan.
Yasunori SaitoSchool of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan.
Shuta OgawaDepartment of Radiology, Fujita Health University Hospital, Toyoake, Aichi, Japan.
Keisuke YasuiSchool of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan.
Fujita Health University · JPFujita Health University Hospital · JP

Funding

Japan Society for the Promotion of Science 19K08107Japan Society for the Promotion of Science 22K12852
6 · The paper itself

Abstract

In single-isocenter multiple-target stereotactic radiotherapy (SIMT-SRT), it is difficult to evaluate both the geometrical accuracy and absorbed dose measurement when irradiating off-isocenter targets. This study aimed to develop a simple quality assurance (QA) method to evaluate off-isocenter irradiation position accuracy in SIMT-SRT and compare its feasibility with that of a commercial device. First, we created two types of inserts and metallic balls with a diameter of 5 mm to be inserted into a commercially available phantom (SIMT phantom). Second, we developed a dedicated analysis software using Python for the Winston-Lutz test (WLT). Third, an image processing software, including the filtered back-projection algorithm, was developed to analyze the images obtained using an electronic portal imaging device (EPID). Fourth, the feasibility of our method was evaluated by comparing it with the results of WLT using two commercially available phantoms: WL-QA and MultiMet-WL cubes. Notably, 92% of the results in one-dimensional deviations were within 0.26 mm (EPID pixel width). The correlation coefficients were 0.52, 0.92, and 0.96 in the left-right, superior-inferior, and anterior-posterior directions, respectively. In the WLT, a maximum two-dimensional deviation of 0.70 mm was detected in our method, while the deviation in the other method was within 0.5 mm. The advantage of our method is that it can evaluate the geometrical accuracy at any gantry angle during dynamic rotation irradiation using a filtered back-projection algorithm, even if the target is located off the isocenter. Our method can perform WLT at arbitrary positions and is suitable for the QA of dynamic rotation irradiation using an EPID.

Indexed as

Particle AcceleratorsRadiosurgeryPhantoms, ImagingQuality Assurance, Health CareRadiotherapy Planning, Computer-AssistedFiltered back projectionGeometrical accuracyOff-isocenterQuality assuranceSIMT-SRT

Identifiers

PMID36261754
OpenAlexW4306809621

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.