Evidence map›Paper›PMID 36258919›Full record

ArticleTanaffos2022

Presentation of Two Simple Methods to Confirm Proper Tracheal Intubation: Palm Pressure, Plastic Bag Inflation, and Bag Pulsation.

Zahid Hussain Khan, Mojgan Rahimi, Kamran Mottaghi, Masoud Nashibi

Abstract read
In one paragraph

Article in Tanaffos, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Zahid Hussain KhanDepartment of Anesthesiology, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran.
Mojgan RahimiDepartment of Anesthesiology, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran.
Kamran MottaghiDepartment of Anesthesiology, Shahid Beheshti University of Medical Sciences, Loghman Hakim Hospital, Tehran, Iran.
Masoud NashibiDepartment of Anesthesiology, Shahid Beheshti University of Medical Sciences, Loghman Hakim Hospital, Tehran, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The correct placement of the endotracheal tube is a cornerstone of safe anesthesia. Different methods, such as auscultation, capnography, and ultrasound, have their own limitations regarding the confirmation of endotracheal intubation, reinforcing the idea that a single technique is not foolproof. This study proposes a new technique in this regard. Materials and Methods: A total of 600 patients were enrolled in this study, and tracheal intubation was checked with palm pressure and disposable plastic glove inflation and pulsation. Results: The data were analyzed using the t-test and Mann-Whitney U test that indicate 94% and 94.8% sensitivity for palm pressure and bag pulsation, respectively, and a 100% positive predictive value for both tests. Conclusion: Palm pressure and bag pulsation are accurate, inexpensive, and reliable techniques to confirm proper tracheal intubation.

Indexed as

Bag inflationBag pulsationPalm pressureTracheal intubation

Identifiers

PMID36258919
PMCPMC9571238

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.