Evidence map›Paper›PMID 36258469›Full record

ArticleOptics express2022

Moiré artifacts reduction in Talbot-Lau X-ray phase contrast imaging using a three-step iterative approach.

Siwei Tao, Yueshu Xu, Ling Bai, Zonghan Tian, Xiang Hao, Cuifang Kuang, Xu Liu

Abstract read
In one paragraph

Article in Optics express, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Siwei Tao
Yueshu Xu
Ling Bai
Zonghan Tian
Xiang Hao
Cuifang Kuang
Xu Liu

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Talbot-Lau X-ray phase contrast imaging is a promising technique in biological imaging since it can provide absorption, differential phase contrast, and dark-field images simultaneously. However, high accuracy motorized translation stages and high stability of the imaging system are needed to avoid moiré artifacts in the reconstructed images. In this work, the effects of the stepping errors and the dose fluctuations on the transmission, differential phase contrast, and dark-field images are theoretically derived and systematically summarized. A novel three-step iterative method is designed for image reconstruction in Talbot-Lau interferometry with phase-stepping errors and dose fluctuations. Phase distributions, phase-stepping errors, and dose fluctuation coefficients are iteratively updated via the least square method until the convergence criteria are met. Moiré artifacts are mostly reduced via the proposed method in both the numerical simulations and experiments. The reconstructed images are highly coincident with the ground truth, which verifies the high accuracy of this method. The proposed algorithm is also compared with other moiré artifacts reduction algorithms, which further demonstrates the high precision of this algorithm. This work is beneficial for reducing the strict requirements for the hardware system in the conventional Talbot-Lau interferometry, such as the high accuracy motorized stages and the X-ray tube with high stability, which is significant for advancing the X-ray phase contrast imaging towards the practical medical applications.

Indexed as

ArtifactsInterferometryImage Processing, Computer-AssistedRadiographyX-Rays

Identifiers

PMID36258469
PMCPMC9662601

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.