Evidence map›Paper›PMID 36257827›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2022

Globefish-Inspired Balloon Catheter with Intelligent Microneedle Coating for Endovascular Drug Delivery.

Xiaoxuan Zhang, Yi Cheng, Rui Liu, Yuanjin Zhao

Open access · goldAbstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 31 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Review
  6. Review
  7. Article
  8. Review
  9. Review
  10. Review
  11. Review
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Xiaoxuan ZhangDepartment of Rheumatology and Immunology, Nanjing Drum Tower Hospital, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China.ORCID 0000-0001-8790-6558
Yi ChengDepartment of Rheumatology and Immunology, Nanjing Drum Tower Hospital, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China.
Rui LiuDepartment of Rheumatology and Immunology, Nanjing Drum Tower Hospital, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China.
Yuanjin ZhaoDepartment of Rheumatology and Immunology, Nanjing Drum Tower Hospital, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China.ORCID 0000-0001-9242-4000
Nanjing Drum Tower Hospital · CN

Funding

National Key Research and Development Program of China 2020YFA0908200National Natural Science Foundation of China 52073060National Natural Science Foundation of China T2225003Shenzhen Fundamental Research Program JCYJ20190813152616459Shenzhen Fundamental Research Program JCYJ20210324133214038
6 · The paper itself

Abstract

Balloon catheters exhibit important values in treating cardiovascular diseases, while their functions are still under improvements. Here, inspired by the thorn-hiding and deflating-inflating characteristics of globefish, intelligent balloon catheters decorated with invisible microneedles are presented for endovascular drug delivery to inhibit postintervention restenosis (PIRS). These microneedle balloon catheters (MNBCs) fabricated by dipping and rolling-assisted template replication contain three coating layers of sandwiched drug-carrying microneedles and black phosphorus (BP)-carrying gelatin. During the emplacement, the microneedles of MNBCs are hidden under the outermost gelatin protective layer, allowing smooth movements inside the blood vessel. After reaching the destination, the embedded BP converts near infrared (NIR) into heat, increases local temperature, and melts the gelatin layer, enabling the exposure and vascular penetration of the microneedles. Besides, as the innermost gelatin also melts, the microneedles can detach from the balloon catheter and be left inside the blood vessel for continuous drug release. Based on advantages of responsiveness, penetration capacity, and biosafety, it is demonstrated that the MNBCs behave satisfactorily in delivering rapamycin to inhibit abdominal aorta restenosis in rats. All these features indicate that these MNBCs are promising medical devices for clinical applications.

Indexed as

PhosphorusAnimalsRatsPhosphorusballoon catheterbioinspireddrug deliverymicroneedlesTrumprestenosis

Identifiers

PMID36257827
PMCPMC9731713
OpenAlexW4306737631

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.