Evidence map›Paper›PMID 36255025›Full record

ArticleEndoscopic ultrasound

Kai Zhang, Nan Ge, Jintao Guo, Sheng Wang, Siyu Sun

Open access · greenAbstract read
In one paragraph

Article in Endoscopic ultrasound. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Kai ZhangDepartment of Gastroenterology, Endoscopic Center, Shengjing Hospital of China Medical University, Shenyang, Liaoning Province, China.
Nan GeDepartment of Gastroenterology, Endoscopic Center, Shengjing Hospital of China Medical University, Shenyang, Liaoning Province, China.
Jintao GuoDepartment of Gastroenterology, Endoscopic Center, Shengjing Hospital of China Medical University, Shenyang, Liaoning Province, China.
Sheng WangDepartment of Gastroenterology, Endoscopic Center, Shengjing Hospital of China Medical University, Shenyang, Liaoning Province, China.
Siyu SunDepartment of Gastroenterology, Endoscopic Center, Shengjing Hospital of China Medical University, Shenyang, Liaoning Province, China.
China Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Objectives: EUS-guided gallbladder drainage (EUS-GBD) has become one of the recommended treatments for patients with high-risk acute cholecystitis. However, the gallbladder reportedly collapsed due to bile leakage, which was a disadvantage that affects the surgical success rate. Different electrocautery-enhanced delivery of the lumen-apposing metal stents (ECE-LAMSs) using suitable power levels in electrosurgical workstations can increase the surgical success rate and reduce trauma. Therefore, we proposed the use of the ECE-LAMSs and electrosurgical workstations for the first time through ex vivo experiments to adjust the different power levels and select the most suitable electrosurgical power for each ECE-LAMS type. Methods: We compared three types of ECE-LAMS (9Fr, 10.5Fr, and 10.8Fr) with three types of electrosurgical workstations during EUS-GBD. GBD was simulated ex vivo under the guidance of an ultrasound endoscope. We performed various power tests to elucidate the ideal electric power for different ECE-LAMS combined with the different types of electrosurgical workstations. Results: For the 10.8Fr ECE-LAMS matched with the Martin, Erbe, and Olympus electrosurgical workstations, the ideal power levels were 200 W, 200 W, and 250W. For the 10.5Fr and 9Fr ECE-LAMS matched with the Martin, Erbe, and Olympus electrosurgical workstations, the ideal power levels were 150 W, 200 W, and 200 W. Conclusion: During the operations, due to low-power levels in the electrosurgical workstations increased the number of cuts, the EUS images were obviously unclear, which affected the success rates of the operations. We suggested different power levels for the different types of LAMS and their matching electrosurgical workstations, which can increase the surgical success rates and reduce surgical injuries.

Indexed as

electrocautery-enhanced delivery of the lumen-apposing metal stentsEUSEUS-guided gallbladder drainage

Identifiers

PMID36255025
PMCPMC9688136
OpenAlexW4283016867

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.