ArticleOrthopaedic surgery2023
The Impact of Coronal Configuration of the Proximal Femur on its Mechanical Properties and the Validation of a New Theoretical Model: Finite Element Analysis and Biomechanical Examination.
Article in Orthopaedic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 9 citations in OpenAlex.
- Treatment Trade-Offs and Choices for Femoral Fractures: A Systematic Review and Meta-Analysis.Orthopaedic surgery · 2025Pooled it
- Factors affecting the anatomical localization of proximal femoral fractures in geriatric patients.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026Article
- Factors associated with intracapsular versus extracapsular hip fracture patterns in elderly patients following low-energy falls: a retrospective analysis from a single tertiary-care center in China.Frontiers in medicine · 2026Article
- Deep learning-aided segmentation combined with finite element analysis reveals a more natural biomechanic of dinosaur fossil.Scientific reports · 2025Article
- Evaluating femoral head collapse risk post-fixation removal: a finite element analysis.Frontiers in bioengineering and biotechnology · 2025Article
- Quantitative computed tomography analysis of proximal femur bone mineral density and its relation to hip fracture risk.Quantitative imaging in medicine and surgery · 2024Article
- Research Progress on the Treatment of Geriatric Intertrochanteric Femur Fractures with Proximal Femur Bionic Nails (PFBNs).Orthopaedic surgery · 2024Review
- A Novel Internal Fixation Design for the Treatment of AO/OTA-31A3.3 Intertrochanteric Fractures: Finite Element Analysis.Orthopaedic surgery · 2024Article
- MRI characteristics of radiographically occult femoral neck fractures in trauma patients with ipsilateral femoral shaft fractures.Emergency radiology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
Abstract
objectiveThis study aims to establish the coronal configuration of the proximal femur as an independent factor for its mechanical properties and provide validation for the theoretical model "fulcrum-balance-reconstruction."
methodsThe digital 3D femur model constructed with the lower extremity high-resolution computed tomography of a senior subject was applied with the axial compression of 2100N under 5 different α angles of 10°, 5°, 0°, -5°, -10°. The equivalent stress distribution of the femoral geometric model under each angle were calculated. Under the same five α angles, fatigue test was performed on 15 composite artificial left femurs (three specimens in each angle group) to obtain the failure cycle and fracture site. The statistical analysis was accomplished using One-Way ANOVA.
resultsThe maximum stress of the entire femur in physiological angle (α = 10°) occurred below femoral neck with a value of 63.91 MPa. When the proximal femur is in extreme abducted angle (α = -10°), the maximum stress shift to the lower medial cortex of femoral shaft with a value of 105.2 MPa. As the α angle changed from 10° to -10°, the greater trochanteric region had the largest increment in maximum stress (2.78 times for cortex and 1.67 times for cancellous bone) locally at the proximal femur. The failure cycles of the artificial femurs with a variety of abduction angle were averagely 9126 ± 2453.87 (α = -10°), 58,112.33 ± 1293.84 (α = -5°), 92,879.67 ± 2398.54 (α = 0°), 172,045.3 ± 11011.11 (α = 5°), and 264,949.3 ± 35,067.26 (α = 10°), and the statistical analysis revealed that the α angle of the group of concern is proportional to the P value of the corresponding group compared to the 10° group(α = 5° & α = 10°, P = 0.01; α = 0 & α = 10°, P = 0.001; α = -5°, -10° & α = 10°, P < 0.001). In fatigue test, the fracture appeared on femoral neck for the α angles of 10° (three subcapital), 5° (two basal; one transcervical), and 0° (one transcervical). Fracture sites located at trochanteric region were observed with the more abducted angles including 0° (two subtrochanteric) and -5° (two intertrochanteric; one subtrochanteric). The fracture line was only found on femoral shaft in the -10° group.
conclusionWith increasing hip abduction, the proximal femur shows declining mechanical properties, which suggests higher risk of hip fracture and increasement in the fraction of trochanteric fracture subtype. Furthermore, the hypothesis of "fulcrum-balance-reconstruction" was validated by our study to a certain extent.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials