Evidence map›Paper›PMID 36250537›Full record

ArticleOrthopaedic surgery2022

Surgical Transepicondylar Axis Is Not a Reliable Reference when there Was Lateral Femoral Bowing.

LiMing Liu, Kai Lei, Lin Guo, Xin Chen, PengFei Yang, DeJie Fu, Ran Xiong, Liu Yang

Abstract read
In one paragraph

Article in Orthopaedic surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

LiMing LiuCenter for Joint Surgery, Southwest Hospital, Third Military Medical University, Chongqing, China.ORCID https://orcid.org/0000-0003-4334-2695
Kai LeiCenter for Joint Surgery, Southwest Hospital, Third Military Medical University, Chongqing, China.ORCID https://orcid.org/0000-0001-6861-7291
Lin GuoCenter for Joint Surgery, Southwest Hospital, Third Military Medical University, Chongqing, China.ORCID https://orcid.org/0000-0003-4718-6706
Xin ChenCenter for Joint Surgery, Southwest Hospital, Third Military Medical University, Chongqing, China.
PengFei YangCenter for Joint Surgery, Southwest Hospital, Third Military Medical University, Chongqing, China.
DeJie FuCenter for Joint Surgery, Southwest Hospital, Third Military Medical University, Chongqing, China.
Ran XiongCenter for Joint Surgery, Southwest Hospital, Third Military Medical University, Chongqing, China.
Liu YangCenter for Joint Surgery, Southwest Hospital, Third Military Medical University, Chongqing, China.

Funding

National Key R&D Program of China 2021YFC2401300National Natural Science Foundation of China 82002357
6 · The paper itself

Abstract

objectiveThe surgical transepicondylar axis (sTEA) is believed to be a consistent reference for femoral rotation axis, and the reliability of its orientation seriously affects the accuracy and outcome of total knee arthroplasty (TKA). This study was designed to investigate the relationship between the orientation of sTEA and femoral bowing angle (FBA) and posterior condylar line (PCL) using three-dimensional (3D) computed tomography (CT) reconstruction models to verify its reliability.

methodsThis study retrospectively collected lower extremity images of 443 southern Chinese osteoarthritic patients (347 women, 96 men; 234 left, 209 right; mean age 66.5 ± 9.3 years) from August 2016 to June 2018. The hip-knee-ankle angle (HKA) was measured on anteroposterior weight-bearing full lower extremity standing radiographs. Measurements on 3D CT models of the femurs included lateral angle between the femoral mechanical axis and sTEA coronal angle, angle between sTEA and distal joint line (distal condylar axis angle, DCA); angle between sTEA and PCL (sTEA axial angle); angle between anatomical axis of proximal femur and anatomical axis of distal femur in the plane they form (actual FBA) and its projection on the coronal (lateral FBA) and sagittal (anterior FBA) planes. The correlations between sTEA coronal angle, sTEA axial angle and actual FBA, lateral FBA, anterior FBA, HKA, DCA were explored using the Spearman correlation test.

resultsThe mean value of actual FBA is (14.4 ± 3.6)°, of lateral FBA is (6.0 ± 4.0)°, and of anterior FBA is (12.7 ± 3.0)°. The mean value of sTEA coronal angle is (88.7 ± 3.6)°, of sTEA axial angle is (2.1 ± 2.8)°. The sTEA coronal angle was positively correlated with actual FBA (r = 0.320, P < 0.01), lateral FBA (r = 0.448, P < 0.01), anterior FBA (r = 0.113, P < 0.05), HKA (r = 0.482, P < 0.01) and DCA (r = 0.486, P < 0.01). The sTEA axial angle was positively correlated with DCA (r = 0.168, P < 0.01), but not significantly correlated with all FBAs and HKA (NS).

conclusionThe sTEA cannot be used as a stable reference when there was an obvious femoral bowing deformity. As the lateral femoral bowing increases, the orientation of sTEA becomes more varus, no matter the knee is varus or valgus.

Indexed as

Reproducibility of ResultsAgedFemaleHumansMiddle AgedRetrospective StudiesComputed tomographyFemoral bowing angleKneeSurgical transepicondylar axisTotal knee arthroplasty

Identifiers

PMID36250537
PMCPMC9732584

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.