ArticlePolish journal of radiology2022
Can clot size and stenotic degree predict perfusion defects on conventional computed tomographic pulmonary angiography in diagnoses of pulmonary embolism?
Article in Polish journal of radiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 3 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: To evaluate clot size and stenotic degree on conventional computed tomographic pulmonary angiography (CTPA) with perfusion defect. Material and Methods: Fifty-two pulmonary embolism (PE) patients with 144 PE locations underwent dual-energy CTPA with an iodine distribution map. Each PE location was rated as to whether there was a perfusion defect. Clot size, stenotic degree, and other associated PE findings were evaluated. These findings were then correlated with whether the perfusion defect was present. Results: There were no associations between demographics, clinical characteristics, anatomical data, and perfusion defect. The median iodine concentration ratio was 0.11. Imaging interpretation by 2 thoracic radiologists had excellent agreement. The clot size and stenotic degree in PE were significant predictors of perfusion defect on conventional CTPA. Lesions with higher degrees of stenosis had higher percentages of perfusion defect. The generalized estimating equation (GEE) logistic regression confirmed that clot size and stenotic degree could predict PE perfusion defects on conventional CTPA. Conclusions: The 2 significant predictors of perfusion defect were occluded vessels in both small and large branches together, or complete occlusion of the pulmonary artery.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.