Evidence map›Paper›PMID 36249639›Full record

ReviewCureus2022

A Review on Glaucoma Drainage Devices and its Complications.

Sajal Gupta, Sandhya Jeria

Open access · diamondAbstract readReview
In one paragraph

Review in Cureus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed, 2 pooled it
4.5field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 2 syntheses or guidelines pooled it, 24 citations in OpenAlex.

  1. The Paul Glaucoma Implant: a systematic review of safety, efficacy, and emerging applications.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2025
    Pooled it
  2. Pooled it
  3. Evaluation of tube extender use in glaucoma management: insights from a cohort study.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
    Article
  4. Article
  5. Article
  6. Review
  7. Efficacy and safety of preserflo™ microshunt in refractory ocular hypertension with or without secondary glaucoma following pars plana vitrectomy.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
    Observational
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Review
  16. Review
  17. Patient Preferences for Long-Term Implant Care in Cochlear, Glaucoma and Cardiovascular Diseases.International journal of environmental research and public health · 2023
    Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Sajal GuptaOphthalmology, Jawaharlal Nehru Medical College, Datta Meghe Institute Of Medical Sciences, Wardha, IND.
Sandhya JeriaOphthalmology, Jawaharlal Nehru Medical College, Datta Meghe Institute Of Medical Sciences, Wardha, IND.
Jawaharlal Nehru Medical College · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Glaucoma is one of the leading causes of blindness in the world. It is an ocular disorder that may have multiple etiologies and which can present as optic neuropathy and increased intraocular pressure (IOP), but in some cases like normotensive glaucoma, the IOP may remain normal. Its gradually progressive nature makes it important for early diagnosis; although the loss of vision is slow, lost vision can't be restored. Glaucoma drainage implant surgeries are an increasingly popular option in recent days in complicated cases of glaucoma where the previous trabeculectomy had failed and medical management was not responsive. Glaucoma drainage devices (GDD) are of various designs; they are implanted according to the patient condition and surgeons' preference. There are complications after the implantation of a GDD like hypotony, endophthalmitis, migration of the plate, extrusion, erosion of the mucous membrane, etc. In the market, there are various drainage devices present, but some of them are frequently used and popular. In this article, we will discuss some most commonly used GDDs and their complications. Among these, four are the most popular: Molteno, Baerveldt, Krupin, and Ahmed. The failure rate of the GDD is low. In many studies, it has been noted that only half of the GDD remains functional after five years. Therefore, further studies are still being conducted to refine the biomaterials, techniques, and shape of the GDD. The technique of surgery is also very much crucial in the success of GDD implantation. The glaucoma type is an essential factor in deciding the treatment, and the outcome of the surgery also depends on it.

Indexed as

ahmedbaerveldtg.d.dglaucomai.o.pkrupinmolteno

Identifiers

PMID36249639
PMCPMC9554953
OpenAlexW4295242432

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.