ArticleHeliyon2022
A closer look at the efficiency calibration of LaBr
Article in Heliyon, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It has been retracted, and should not be counted. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
- Retraction · 2026-01-13Concerns/Issues about Referencing/Attributions · Investigation by Journal/Publisher · Objections by Author(s) · Unreliable Results and/or Conclusions ·
- Retracted
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The nuclear spectroscopy method has long been used for advanced studies on nuclear physics. In order to decrease costs and increase the efficiency of nuclear radiation investigations, quick and efficient solutions are required. The purpose of this research was to calculate the whole energy peak efficiency values for a range of gamma-ray energies, from 30.973 keV to 1408 keV, at various source-detector distances using the MCNPX Monte Carlo code, which is extensively used in nuclear medicine, industry, and scientific research. As a result, the modeled detectors' full-energy peak efficiencies were calculated and compared to both experimental data and Monte Carlo simulations. Experiment results and prior studies using Monte Carlo simulations were found to be very consistent with these results. The counting efficiency against source-detector distance is then calculated using the modeled detectors. The data we have show that LaBr
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.