ArticleOphthalmology science2022
Early Glaucoma Detection by Using Style Transfer to Predict Retinal Nerve Fiber Layer Thickness Distribution on the Fundus Photograph.
Article in Ophthalmology science, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 21 citations in OpenAlex.
- Deriving OCT-Equivalent Retinal Nerve Fiber Layer Thickness Maps from Fundus Photographs with Deep Learning Improves Glaucoma Diagnosis.Ophthalmology science · 2026Article
- Improving Generalization of Deep Learning for Glaucoma Classification Under Real-World Domain Shift via Unsupervised Domain Adaptation.Translational vision science & technology · 2026Article
- Deep Learning-Based Generation of Retinal Nerve Fibre Layer Thickness Maps from Fundus Photographs: A Comparative Analysis of U-Net Architectures for Accessible Glaucoma Assessment.Life (Basel, Switzerland) · 2026Article
- BDNet: A Real-Time Biomedical Image Denoising Network with Gradient Information Enhancement Loss.Biosensors · 2026Article
- Generative artificial intelligence in ophthalmology: a scoping review of current applications, opportunities, and challenges.Eye (London, England) · 2025Article
- The Role of Artificial Intelligence in Predicting the Progression of Intraocular Hypertension to Glaucoma.Life (Basel, Switzerland) · 2025Article
- Generative Adversarial Networks in Medicine: Important Considerations for this Emerging Innovation in Artificial Intelligence.Annals of biomedical engineering · 2023Review
- Comprehensive Review on the Use of Artificial Intelligence in Ophthalmology and Future Research Directions.Diagnostics (Basel, Switzerland) · 2022Review
- Application of artificial intelligence in glaucoma care: An updated review.Taiwan journal of ophthalmologyReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective: We aimed to develop a deep learning (DL)-based algorithm for early glaucoma detection based on color fundus photographs that provides information on defects in the retinal nerve fiber layer (RNFL) and its thickness from the mapping and translating relations of spectral domain OCT (SD-OCT) thickness maps. Design: Developing and evaluating an artificial intelligence detection tool. Subjects: Pretraining paired data of color fundus photographs and SD-OCT images from 189 healthy participants and 371 patients with early glaucoma were used. Methods: The variational autoencoder (VAE) network training architecture was used for training, and the correlation between the fundus photographs and RNFL thickness distribution was determined through the deep neural network. The reference standard was defined as a vertical cup-to-disc ratio of ≥0.7, other typical changes in glaucomatous optic neuropathy, and RNFL defects. Convergence indicates that the VAE has learned a distribution that would enable us to produce corresponding synthetic OCT scans. Main Outcome Measures: Similarly to wide-field OCT scanning, the proposed model can extract the results of RNFL thickness analysis. The structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR) were used to assess signal strength and the similarity in the structure of the color fundus images converted to an RNFL thickness distribution model. The differences between the model-generated images and original images were quantified. Results: We developed and validated a novel DL-based algorithm to extract thickness information from the color space of fundus images similarly to that from OCT images and to use this information to regenerate RNFL thickness distribution images. The generated thickness map was sufficient for clinical glaucoma detection, and the generated images were similar to ground truth (PSNR: 19.31 decibels; SSIM: 0.44). The inference results were similar to the OCT-generated original images in terms of the ability to predict RNFL thickness distribution. Conclusions: The proposed technique may aid clinicians in early glaucoma detection, especially when only color fundus photographs are available.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.