Evidence map›Paper›PMID 36245759›Full record

ArticleOphthalmology science2022

Early Glaucoma Detection by Using Style Transfer to Predict Retinal Nerve Fiber Layer Thickness Distribution on the Fundus Photograph.

Henry Shen-Lih Chen, Guan-An Chen, Jhen-Yang Syu, Lan-Hsin Chuang, Wei-Wen Su, Wei-Chi Wu, Jian-Hong Liu, Jian-Ren Chen, Su-Chen Huang, Eugene Yu-Chuan Kang

Open access · goldAbstract read
In one paragraph

Article in Ophthalmology science, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.6field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Henry Shen-Lih ChenDepartment of Ophthalmology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan.
Guan-An ChenHealthcare Service Division, Department of Intelligent Medical & Healthcare, Service Systems Technology Center, Industrial Technology Research Institute, Hsinchu, Taiwan.
Jhen-Yang SyuHealthcare Service Division, Department of Intelligent Medical & Healthcare, Service Systems Technology Center, Industrial Technology Research Institute, Hsinchu, Taiwan.
Lan-Hsin ChuangCollege of Medicine, Chang Gung University, Taoyuan, Taiwan.
Wei-Wen SuDepartment of Ophthalmology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan.
Wei-Chi WuDepartment of Ophthalmology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan.
Jian-Hong LiuHealthcare Service Division, Department of Intelligent Medical & Healthcare, Service Systems Technology Center, Industrial Technology Research Institute, Hsinchu, Taiwan.
Jian-Ren ChenHealthcare Service Division, Department of Intelligent Medical & Healthcare, Service Systems Technology Center, Industrial Technology Research Institute, Hsinchu, Taiwan.
Su-Chen HuangHealthcare Service Division, Department of Intelligent Medical & Healthcare, Service Systems Technology Center, Industrial Technology Research Institute, Hsinchu, Taiwan.
Eugene Yu-Chuan KangDepartment of Ophthalmology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan.
Chang Gung University · TWIndustrial Technology Research Institute · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: We aimed to develop a deep learning (DL)-based algorithm for early glaucoma detection based on color fundus photographs that provides information on defects in the retinal nerve fiber layer (RNFL) and its thickness from the mapping and translating relations of spectral domain OCT (SD-OCT) thickness maps. Design: Developing and evaluating an artificial intelligence detection tool. Subjects: Pretraining paired data of color fundus photographs and SD-OCT images from 189 healthy participants and 371 patients with early glaucoma were used. Methods: The variational autoencoder (VAE) network training architecture was used for training, and the correlation between the fundus photographs and RNFL thickness distribution was determined through the deep neural network. The reference standard was defined as a vertical cup-to-disc ratio of ≥0.7, other typical changes in glaucomatous optic neuropathy, and RNFL defects. Convergence indicates that the VAE has learned a distribution that would enable us to produce corresponding synthetic OCT scans. Main Outcome Measures: Similarly to wide-field OCT scanning, the proposed model can extract the results of RNFL thickness analysis. The structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR) were used to assess signal strength and the similarity in the structure of the color fundus images converted to an RNFL thickness distribution model. The differences between the model-generated images and original images were quantified. Results: We developed and validated a novel DL-based algorithm to extract thickness information from the color space of fundus images similarly to that from OCT images and to use this information to regenerate RNFL thickness distribution images. The generated thickness map was sufficient for clinical glaucoma detection, and the generated images were similar to ground truth (PSNR: 19.31 decibels; SSIM: 0.44). The inference results were similar to the OCT-generated original images in terms of the ability to predict RNFL thickness distribution. Conclusions: The proposed technique may aid clinicians in early glaucoma detection, especially when only color fundus photographs are available.

Indexed as

AutoencoderDL, deep learningDNN, deep neural networkGAN, generative adversarial networkGlaucomaImage-to-image translationOCTPSNR, peak signal-to-noise ratioRetinal nerve fiber layer thicknessRNFL, retinal nerve fiber layerSD-OCT, spectral domain optical coherence tomographySSIM, structural similarity index measureVAE, variational autoencoder

Identifiers

PMID36245759
PMCPMC9559108
OpenAlexW4286885316

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.