Evidence map›Paper›PMID 36241854›Full record

Observational studyScientific reports2022

A comparison of the ClotPro system with rotational thromboelastometry in cardiac surgery: a prospective observational study.

Ryogo Yoshii, Teiji Sawa, Hidetake Kawajiri, Fumimasa Amaya, Kenichi A Tanaka, Satoru Ogawa

Abstract readObservational Study
In one paragraph

Observational study in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed.

  1. Article
  2. Observational
  3. ClotProBMC pregnancy and childbirth · 2026
    Observational
  4. Four new markers of early thrombotic molecules and thromboelastography in prognostic evaluation of AMI patients undergoing PCI.The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology · 2026
    Review
  5. Article
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
  11. Review
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. The establishment of reference intervals for the ClotPro thromboelastometry device in healthy dogs.Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001)
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ryogo YoshiiDepartment of Anesthesiology, Kyoto Prefectural University of Medicine, Kyoto, Japan.
Teiji SawaDepartment of Anesthesiology, Kyoto Prefectural University of Medicine, Kyoto, Japan.
Hidetake KawajiriDepartment of Cardiovascular Surgery, Kyoto Prefectural University of Medicine, Kyoto, Kyoto, Japan.
Fumimasa AmayaDepartment of Pain Management and Palliative Care Medicine, Kyoto Prefectural University of Medicine, Kawaramachi Hirokoji, Kamigyo, Kyoto, 602-8566, Japan.
Kenichi A TanakaDepartment of Anesthesiology, University of Oklahoma Health Sciences Center, Oklahoma, USA.
Satoru OgawaDepartment of Anesthesiology, Kyoto Prefectural University of Medicine, Kyoto, Japan. s-ogawa@koto.kpu-m.ac.jp.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Viscoelastic coagulation tests have been increasingly used for hemostasis management in cardiac surgery. The ClotPro system is a novel viscoelastic device based on principles of rotational thromboelastometry. We aimed to compare ClotPro with ROTEM and plasma coagulation assays in cardiopulmonary bypass (CPB) patients. Blood samples were collected from 25 CPB patients at (1) baseline, (2) start of CPB, (3) end of CPB, and (4) end of surgery. The EX-test, IN-test, HI-test, FIB-test parameters on ClotPro were compared with corresponding ROTEM assay (EXTEM, INTEM, HEPTEM, and FIBTEM). Standard plasma coagulation assays and endogenous thrombin generation (TG) were simultaneously evaluated. Pearson correlation analyses showed moderate correlations between clotting times (CTs) (r = 0.63-0.67; p < 0.001, respectively), and strong correlations with maximal clot firmness (MCF) (r = 0.93-0.98; p < 0.001, respectively) between ClotPro and ROTEM. EX-test and IN-test MCF parameters were interchangeable with acceptable percentage errors (EX-test MCF: 7.3%, IN-test MCF: 8.3%), but FIB-test MCF (27.0%) and CT results were not (EX-test CT: 44.7%, IN-test CT: 31.4%). The correlations of PT/INR or peak TG with EX-test CTs were higher than with EXTEM CTs (PT/INR: r = 0.80 and 0.41, peak TG: 0.43 and 0.18, respectively). FIB-test MCF has strong correlation with plasma fibrinogen and factor XIII level (r = 0.84 and 0.66, respectively). ROC analyses showed that ClotPro was capable of emulating well-established ROTEM thresholds (area under curves: 0.83-1.00). ClotPro demonstrated strong correlations in MCF parameters of ROTEM in CPB patients. It may be reasonable to modify ROTEM-based transfusion algorithm pertaining to MCF parameters to establish cut-off values for ClotPro device.

Indexed as

Cardiac Surgical ProceduresThrombelastographyBlood CoagulationBlood Coagulation TestsFactor XIIIFibrinogenHumansThrombinFactor XIIIFibrinogenThrombin

Identifiers

PMID36241854
PMCPMC9568545

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.