Evidence map›Paper›PMID 36238972›Full record

ArticleOrthopaedic surgery2022

Comparison of Tibial Tubercle Landmark Technique and Range of Motion Technique in Primary Total Knee Arthroplasty: A Retrospective Cohort Study.

Liu Xin, Mao Xingjia, Guo Shengjie, Cao Yanwei, Li Shuaijie, Xiang Chuan

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Liu XinDepartment of Orthopaedic Surgery, The Second Hospital of Shanxi Medical University, Taiyuan, China.
Mao XingjiaDepartment of Orthopaedic Surgery, The Second Hospital of Shanxi Medical University, Taiyuan, China.
Guo ShengjieDepartment of Orthopaedic Surgery, The Second Hospital of Shanxi Medical University, Taiyuan, China.
Cao YanweiDepartment of Orthopaedic Surgery, The Second Hospital of Shanxi Medical University, Taiyuan, China.
Li ShuaijieDepartment of Orthopaedic Surgery, The Second Hospital of Shanxi Medical University, Taiyuan, China.
Xiang ChuanDepartment of Orthopaedic Surgery, The Second Hospital of Shanxi Medical University, Taiyuan, China.ORCID https://orcid.org/0000-0002-1121-6443
Shanxi Medical University · CN

Funding

Xiang Chuan 201803D421050Xiang Chuan 81972075
6 · The paper itself

Abstract

objectiveThere is not a standard for rotational alignment of the tibial component in total knee arthroplasty (TKA). For now, the most commonly methods are tibial-tubercle -landmark technique (TTL) and range-of-motion technique (ROM). The study is aimed to compare clinical outcomes and radiographic data of patients who undergone primary TKA with TTL or ROM technique.

methodsThis single-surgeon retrospective cohort study includes 60 patients with TTL technique and 60 with ROM technique from December 2017 to January 2019. All patients were evaluated clinically using Hospital for Special Surgery Knee Score (HSS), Feller patellar score, visual analogue scale (VAS) and maximum knee flexion and extension angle before and after surgery at both 6 months and 12 months postoperatively. Radiographic data contain hip-knee-ankle angle (HKA), mechanical lateral distal femoral angle (mLDFA), mechanical medial proximal tibial angle (mMPTA), posterior slope angle (PSA) on pre and postoperative X-ray and rotation angle of femoral component (relative to surgical trans-epicondylar axis) and tibial component (relative to surgical trans-epicondylar axis, tibial posterior condylar line and Akagi') on postoperative computed tomography (CT) scan. Clinical outcomes and radiological data were compared between the two groups.

resultsOne hundred twenty patients (120 knees) were enrolled in this study, including 38 males and 82 females, aged from 58 to 78, with an average of 65.7 years. There was no significant difference in demographics and preoperative X-ray data between the two groups (P > 0. 05). Clinical scores of the TTL group were better than those in the ROM group at 6 and 12 months after surgery, when comparing HSS (83.57 ± 5.00 vs 75.90 ± 4.89, F = 59.004, P < 0.001; 90.53 ± 4.31 vs 82.83 ± 4.98, F = 54.509, P < 0.001), Feller patellar score (21.43 ± 2.54 vs 19.10 ± 2.52, F = 14.864, P = 0.001; 26.27 ± 1.98 vs 23.20 ± 2.31, F = 42.204, P < 0.001) and VAS (3.70 ± 0.62 vs 4.38 ± 0.92, F = 14.508, P = 0.001; 2.10 ± 0.90 vs 2.79 ± 0.80, F = 11.554, P = 0.002). But there was no significant difference in the flexion and extension angle between the two groups. In imaging evaluation, no statistical difference was found in pre- and postoperative HKA, mLDFA, mMPTA and PSA. Rotational angles of tibial component only did relative to Akagi' have statistical difference in two groups (2.33 ± 4.3 vs 4.41 ± 3.2, t = 2.143, P < 0.05) (Positive value represented external rotation).

conclusionThe results of our study showed that both methods were reliable, and TTL technique provided better clinical scores and larger external angle of tibial component, compared to ROM technique.

Indexed as

Arthroplasty, Replacement, KneeHumansRetrospective StudiesAlignmentROM techniqueTibial rotationTotal knee arthroplastyTTL technique

Identifiers

PMID36238972
PMCPMC9732623
OpenAlexW4306160050

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.