Placement of catheters without magnetic sensors in the coronary sinus without fluoroscopic guidance: Feasibility and safety evaluation.

Tadashi Hoshiyama, Hitoshi Sumi, Shozo Kaneko, Yusei Kawahara, Miwa Ito, Hisanori Kanazawa, Seiji Takashio, Eiichiro Yamamoto, Kenichi Matsushita, Kenichi Tsujita

Open access · goldAbstract read
In one paragraph

Article in Journal of arrhythmia, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 49% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Tadashi HoshiyamaDepartment of Cardiovascular Medicine, Graduate School of Medical Sciences Kumamoto University Kumamoto Japan.ORCID https://orcid.org/0000-0002-1315-5904
Hitoshi SumiDepartment of Cardiovascular Medicine, Graduate School of Medical Sciences Kumamoto University Kumamoto Japan.
Shozo KanekoDepartment of Cardiovascular Medicine, Graduate School of Medical Sciences Kumamoto University Kumamoto Japan.
Yusei KawaharaDepartment of Cardiovascular Medicine, Graduate School of Medical Sciences Kumamoto University Kumamoto Japan.
Miwa ItoDepartment of Cardiovascular Medicine, Graduate School of Medical Sciences Kumamoto University Kumamoto Japan.
Hisanori KanazawaDepartment of Cardiovascular Medicine, Graduate School of Medical Sciences Kumamoto University Kumamoto Japan.
Seiji TakashioDepartment of Cardiovascular Medicine, Graduate School of Medical Sciences Kumamoto University Kumamoto Japan.
Eiichiro YamamotoDepartment of Cardiovascular Medicine, Graduate School of Medical Sciences Kumamoto University Kumamoto Japan.
Kenichi MatsushitaDepartment of Cardiovascular Medicine, Graduate School of Medical Sciences Kumamoto University Kumamoto Japan.
Kenichi TsujitaDepartment of Cardiovascular Medicine, Graduate School of Medical Sciences Kumamoto University Kumamoto Japan.
Kumamoto University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: A three-dimensional (3D) mapping system is essential to reduce radiation exposure during catheter ablation. When using the CARTO 3D mapping system, only the catheter with magnetic sensor can visualize its location. However, once target chamber matrix is created using the catheter, even the catheters without magnetic sensors (CWMS) can enable visualization. We aimed to investigate the feasibility and safety of placing a CWMS in the coronary sinus (CS) without fluoroscopic guidance. Methods: The study group comprised 88 consecutive patients who underwent catheter ablation. CWMS placement was performed without fluoroscopic guidance in 47 patients and with fluoroscopic guidance in 41 patients. Placement without fluoroscopic guidance was performed after creating a visualization matrix of the CS, right atrium, and superior vena cava using a catheter with a magnetic sensor. Feasibility and safety were compared between the two groups. Results: Successful catheter placement was achieved in all patients without fluoroscopic guidance, with no inter-group difference in the median procedure time: with guidance, 120.0 [96.0-135.0] min, and without guidance, 110.0 [97.5-125.0] min; Conclusions: CWMS placement without fluoroscopic guidance is feasible, safe to perform, and does not involve complications. Our technique provides an option to decrease radiation exposure during catheter ablation and electrophysiological testing.

Indexed as

catheter ablationradiation exposurethree‐dimensional mapping

Identifiers

PMID36237862
PMCPMC9535797
OpenAlexW4289861496

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.