Evidence map›Paper›PMID 36237610›Full record

ArticleFrontiers in neurology2022

Stent-assisted coiling using the Neuroform Atlas stent for treatment of aneurysms that recur after coil embolization.

Linggen Dong, Jiejun Wang, Xiheng Chen, Longhui Zhang, Zhiqiang Zhao, Qichen Peng, Zeping Jin, Jun Wu, Ming Lv, Peng Liu

Abstract read
In one paragraph

Article in Frontiers in neurology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Linggen DongDepartment of Neurointervention, Beijing Neurosurgical Institute, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
Jiejun WangDepartment of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
Xiheng ChenDepartment of Neurointervention, Beijing Neurosurgical Institute, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
Longhui ZhangDepartment of Neurointervention, Beijing Neurosurgical Institute, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
Zhiqiang ZhaoDepartment of Neurointervention, Beijing Neurosurgical Institute, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
Qichen PengDepartment of Neurointervention, Beijing Neurosurgical Institute, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
Zeping JinDepartment of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
Jun WuDepartment of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
Ming LvDepartment of Neurointervention, Beijing Neurosurgical Institute, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
Peng LiuDepartment of Neurointervention, Beijing Neurosurgical Institute, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To evaluate the safety and efficacy of stent-assisted coiling (SAC) using the Neuroform Atlas stent for aneurysms that recur after coil embolization. Methods: We retrospectively reviewed patients who underwent SAC using the Neuroform Atlas stent to treat aneurysms that recurred after coil embolization from November 2020 to November 2021. Patient and aneurysm characteristics, procedural details, complications, and angiographic and clinical follow-up outcomes were recorded and analyzed. Results: Eleven patients with 11 recurrent aneurysms were included for analysis. Atlas stent deployment was successful in all cases. Angiography immediately after the SAC procedure and at last follow-up showed complete occlusion in 10 patients (90.9%) and a residual neck in one (9.1%). Mean angiographic and clinical follow-ups were 9.2 and 10 months, respectively. A single procedure-related complication occurred, mildly blurred vision in the left eye, which recovered completely. No permanent morbidity or mortality occurred. Conclusion: SAC using the Atlas stent to treat aneurysms that recur after coil embolization is safe and effective. Large-scale studies with long-term follow-up are warranted to confirm our results.

Indexed as

endovascular treatmentNeuroform Atlas stentpreviously coiledrecurrent aneurysmsstent-assisted coiling

Identifiers

PMID36237610
PMCPMC9552843

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.