Evidence map›Paper›PMID 36237228›Full record

ArticleEuropean heart journal. Case reports2022

Mind the gap: avoiding paravalvular leak using computer simulation in bicuspid transcatheter aortic valve replacement-a case report.

James Dargan, Rumneek Hampal, Faisal Khan, Stephen Brecker

Open access · goldAbstract readCase Reports
In one paragraph

Article in European heart journal. Case reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

James DarganCardiovascular Clinical Academic Group, St George's University of London and St George's University Hospitals NHS Foundation Trust, Cranmer Terrace, London SW17 0RE, UK.ORCID https://orcid.org/0000-0001-9790-2059
Rumneek HampalSt George's University Hospitals NHS Foundation Trust, Blackshaw Rd, London SW17 0QT, UK.
Faisal KhanSt George's University Hospitals NHS Foundation Trust, Blackshaw Rd, London SW17 0QT, UK.
Stephen BreckerCardiovascular Clinical Academic Group, St George's University of London and St George's University Hospitals NHS Foundation Trust, Cranmer Terrace, London SW17 0RE, UK.ORCID https://orcid.org/0000-0003-2079-0495
St George’s University Hospitals NHS Foundation Trust · GBSt George's, University of London · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Transcatheter aortic valve replacement (TAVR) is becoming increasingly prevalent worldwide and is now more common than surgical aortic valve replacement. It is expanding into all patient subsets including younger and lower risk patients. Bicuspid aortic valve (BAV) accounts for a significant proportion of TAVR, but due to heterogenous anatomy, it is of increased complexity. One of the greatest challenges in BAV is the selection of the correct TAVR size. Transcatheter aortic valve replacement sizing is based upon computed tomography-derived annular measurements. There are a number of sizing algorithms for BAV based upon anatomical characteristics, often yielding different results. This is noted especially when a patient falls near the borderline between two valve sizes, an anatomical grey zone. Complementary to the algorithm approach is the use of pre-procedural patient-specific computer simulation using finite-element modelling. Case summary: An 86-year-old female was treated for heart failure secondary to severe and calcific BAV aortic stenosis with TAVR. Due to anatomical difficulty and grey-zone valve sizing, we demonstrate the use of pre-procedural patient-specific computer simulation with the novel Medtronic Evolut PRO+ platform to achieve a good result. Discussion: Using patient-specific computer simulation, we were able to safely select the valve and the deployment height and then accurately predict the result in a difficult, severely calcified BAV. In addition to improving outcome, this allows for patient-specific, tailored discussion to occur at heart team meetings.

Indexed as

Bicuspid aortic valveCase reportTAVR sizing

Identifiers

PMID36237228
PMCPMC9552996
OpenAlexW4297476711

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.