Evidence map›Paper›PMID 36236788›Full record

ArticleSensors (Basel, Switzerland)2022

Trunk Posture from Randomly Oriented Accelerometers.

Aidan R W Friederich, Musa L Audu, Ronald J Triolo

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Aidan R W FriederichDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.ORCID 0000-0002-1833-2471
Musa L AuduDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.ORCID 0000-0001-5737-1708
Ronald J TrioloDepartment of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106, USA.ORCID 0000-0003-0984-5803
Louis Stokes Cleveland VA Medical Center · US

Funding

Automatic Control of Standing Balance with Functional Neuromuscular StimulationR01NS040547 · NINDS · CASE WESTERN RESERVE UNIVERSITY · PI AUDU, MUSA L, TRIOLO, RONALD J · 2000 to 2022
$7.2M
Integrated Neural Engineering and Rehabilitation Training ProgramT32EB004314 · NIBIB · CASE WESTERN RESERVE UNIVERSITY · PI Jeffrey R Capadona, Robert F. Kirsch · 2004 to 2026
$6.1M
Enhancing Seated Stability and Reaching After Spinal Cord InjuryR01NS101043 · NINDS · CASE WESTERN RESERVE UNIVERSITY · PI AUDU, MUSA L, TRIOLO, RONALD J · 2018 to 2021
$1.7M
NIBIB NIH HHS T32 EB004314NIH HHS R01NS101043NIH HHS T32EB004314NINDS NIH HHS R01 NS040547NINDS NIH HHS R01 NS101043RRD VA IK6 RX003844
6 · The paper itself

Abstract

Feedback control of functional neuromuscular stimulation has the potential to improve daily function for individuals with spinal cord injuries (SCIs) by enhancing seated stability. Our fully implanted networked neuroprosthesis (NNP) can provide real-time feedback signals for controlling the trunk through accelerometers embedded in modules distributed throughout the trunk. Typically, inertial sensors are aligned with the relevant body segment. However, NNP implanted modules are placed according to surgical constraints and their precise locations and orientations are generally unknown. We have developed a method for calibrating multiple randomly oriented accelerometers and fusing their signals into a measure of trunk orientation. Six accelerometers were externally attached in random orientations to the trunks of six individuals with SCI. Calibration with an optical motion capture system resulted in RMSE below 5° and correlation coefficients above 0.97. Calibration with a handheld goniometer resulted in RMSE of 7° and correlation coefficients above 0.93. Our method can obtain trunk orientation from a network of sensors without

Indexed as

Muscle, SkeletalSpinal Cord InjuriesAccelerometryHumansMotionPostureaccelerometerneuroprosthesissensor fusionspinal cord injury

Identifiers

PMID36236788
PMCPMC9573549
OpenAlexW4304172304

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.