Evidence map›Paper›PMID 36236758›Full record

ArticleSensors (Basel, Switzerland)2022

Electrotactile Communication via Matrix Electrode Placed on the Torso Using Fast Calibration, and Static vs. Dynamic Encoding.

Jovana Malešević, Miloš Kostić, Fabricio A Jure, Erika G Spaich, Strahinja Došen, Vojin Ilić, Goran Bijelić, Matija Štrbac

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jovana MaleševićTecnalia Serbia, Ltd., 11000 Belgrade, Serbia.ORCID 0000-0002-4487-9999
Miloš KostićTecnalia Serbia, Ltd., 11000 Belgrade, Serbia.ORCID 0000-0003-1299-4252
Fabricio A JureNeurorehabilitation Systems, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, 9220 Aalborg, Denmark.ORCID 0000-0003-1204-963X
Erika G SpaichNeurorehabilitation Systems, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, 9220 Aalborg, Denmark.ORCID 0000-0003-1275-4064
Strahinja DošenNeurorehabilitation Systems, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, 9220 Aalborg, Denmark.ORCID 0000-0003-3035-147X
Vojin IlićDepartment of Computing and Control Engineering, Faculty of Technical Sciences, University of Novi Sad, 21102 Novi Sad, Serbia.
Goran BijelićTecnalia, Basque Research and Technology Alliance (BRTA), 20009 Donostia-San Sebastian, Spain.
Matija ŠtrbacTecnalia Serbia, Ltd., 11000 Belgrade, Serbia.

Funding

European Commission 883315
6 · The paper itself

Abstract

Electrotactile stimulation is a technology that reproducibly elicits tactile sensations and can be used as an alternative channel to communicate information to the user. The presented work is a part of an effort to develop this technology into an unobtrusive communication tool for first responders. In this study, the aim was to compare the success rate (SR) between discriminating stimulation at six spatial locations (static encoding) and recognizing six spatio-temporal patterns where pads are activated sequentially in a predetermined order (dynamic encoding). Additionally, a procedure for a fast amplitude calibration, that includes a semi-automated initialization and an optional manual adjustment, was employed and evaluated. Twenty subjects, including twelve first responders, participated in the study. The electrode comprising the 3 × 2 matrix of pads was placed on the lateral torso. The results showed that high SRs could be achieved for both types of message encoding after a short learning phase; however, the dynamic approach led to a statistically significant improvement in messages recognition (SR of 93.3%), compared to static stimulation (SR of 83.3%). The proposed calibration procedure was also effective since in 83.8% of the cases the subjects did not need to adjust the stimulation amplitude manually.

Indexed as

TorsoTouchCalibrationCommunicationElectric StimulationElectrodesHumansfeedback codinghapticsmulti-pad electrodetactile communication

Identifiers

PMID36236758
PMCPMC9572222

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.