Evidence map›Paper›PMID 36236659›Full record

ArticleSensors (Basel, Switzerland)2022

Real-Time Non-Contact Millimeter Wave Radar-Based Vital Sign Detection.

Zhiqiang Gao, Luqman Ali, Cong Wang, Ruizhi Liu, Chunwei Wang, Cheng Qian, Hokun Sung, Fanyi Meng

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Motion Mitigation Techniques for Abdominal and Cardiac MR Imaging.Journal of magnetic resonance imaging : JMRI · 2026
    Review
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Zhiqiang GaoSchool of Astronautics, Harbin Institute of Technology, Harbin 150001, China.
Luqman AliSchool of Information and Communication, Harbin Institute of Technology, Harbin 150001, China.ORCID 0000-0002-5893-8232
Cong WangSchool of Information and Communication, Harbin Institute of Technology, Harbin 150001, China.ORCID 0000-0002-2863-0309
Ruizhi LiuSchool of Astronautics, Harbin Institute of Technology, Harbin 150001, China.ORCID 0000-0001-9265-9141
Chunwei WangSchool of Astronautics, Harbin Institute of Technology, Harbin 150001, China.
Cheng QianOcean College, Zhejiang University, Hangzhou 310027, China.
Hokun SungKorea Advanced Nano Fab Center (KANC), Suwon-si 443270, Korea.
Fanyi MengSchool of Information and Communication, Harbin Institute of Technology, Harbin 150001, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this paper, the extraction of the life activity spectrum based on the millimeter (mm) wave radar is designed to realize the detection of target objects and the threshold trigger module. The maximum likelihood estimation method is selected to complete the design of the average early warning probability trigger function. The threshold trigger module is designed for the echo signal of static objects in the echo signal. It will interfere with the extraction of Doppler frequency shift results. The moving target detection method is selected, and the filter is designed. The static clutter interference is filtered without affecting the phase difference between the detection sequences, and the highlight target signal is improved. The frequency and displacement of thoracic movement are used as the detection data. Through the Fourier transform calculation of the sequence, the spectrum value is extracted within the estimated range of the heartbeat and respiration spectrum, and the heartbeat and respiration signals are picked up. The proposed design uses Modelsim and Quartus for CO-simulation to complete the simulation verification of the function, extract the number of logical units occupied by computing resources, and verify the algorithm with the vital signs experiment. The heartbeat and respiration were detected using the sports bracelet; the relative errors of heartbeat detection were 0-6.3%, the respiration detection was 0-9.5%, and the relative errors of heartbeat detection were overwhelmingly less than 5%.

Indexed as

RadarSignal Processing, Computer-AssistedAlgorithmsDoppler EffectFourier AnalysisHeart RateVital SignsdetectionDoppler frequency shiftFourier transformheartbeat detectionmm-wave radar

Identifiers

PMID36236659
PMCPMC9573470

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.