Evidence map›Paper›PMID 36236510›Full record

ArticleSensors (Basel, Switzerland)2022

Earable Ω (OMEGA): A Novel Clenching Interface Using Ear Canal Sensing for Human Metacarpophalangeal Joint Control by Functional Electrical Stimulation.

Kazuhiro Matsui, Yuya Suzuki, Keita Atsuumi, Miwa Nagai, Shotaro Ohno, Hiroaki Hirai, Atsushi Nishikawa, Kazuhiro Taniguchi

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Kazuhiro MatsuiGraduate School of Engineering Science, Osaka University, Toyonaka 560-8531, Osaka, Japan.ORCID 0000-0003-0634-2194
Yuya SuzukiGraduate School of Engineering Science, Osaka University, Toyonaka 560-8531, Osaka, Japan.
Keita AtsuumiGraduate School of Engineering Science, Osaka University, Toyonaka 560-8531, Osaka, Japan.
Miwa NagaiGraduate School of Engineering Science, Osaka University, Toyonaka 560-8531, Osaka, Japan.
Shotaro OhnoGraduate School of Engineering Science, Osaka University, Toyonaka 560-8531, Osaka, Japan.
Hiroaki HiraiGraduate School of Engineering Science, Osaka University, Toyonaka 560-8531, Osaka, Japan.
Atsushi NishikawaGraduate School of Engineering Science, Osaka University, Toyonaka 560-8531, Osaka, Japan.ORCID 0000-0001-5669-1726
Kazuhiro TaniguchiGraduate School of Engineering Science, Osaka University, Toyonaka 560-8531, Osaka, Japan.ORCID 0000-0001-5774-5124
The University of Osaka · JPHiroshima City University · JPYasuda Women's University · JP

Funding

JSPS KAKENHI JP19K12828Kaken Pharmaceutical (Japan) JP20K14693Kaken Pharmaceutical (Japan) JP22K12853
6 · The paper itself

Abstract

(1) Background: A mouth-free interface is required for functional electrical stimulation (FES) in people with spinal cord injuries. We developed a novel system for clenching the human metacarpophalangeal (MP) joint using an earphone-type ear canal movement sensor. Experiments to control joint angle and joint stiffness were performed using the developed system. (2) Methods: The proposed FES used an equilibrium point control signal and stiffness control signal: electrical agonist-antagonist ratio and electrical agonist-antagonist sum. An angle sensor was used to acquire the joint angle, and system identification was utilized to measure joint stiffness using the external force of a robot arm. Each experiment included six and five subjects, respectively. (3) Results: While the joint angle could be controlled well by clenching with some hysteresis and delay in three subjects, it could not be controlled relatively well after hyperextension in the other subjects, which revealed a calibration problem and a change in the characteristics of the human MP joint caused by hyperextension. The joint stiffness increased with the clenching amplitude in five subjects. In addition, the results indicated that viscosity can be controlled. (4) Conclusions: The developed system can control joint angle and stiffness. In future research, we will develop a method to show that this system can control the equilibrium point and stiffness simultaneously.

Indexed as

Ear CanalSpinal Cord InjuriesElectric StimulationHumansMetacarpophalangeal JointMovementclenchingear canal sensorfingerfunctional electrical stimulationspinal cord injury

Identifiers

PMID36236510
PMCPMC9570975
OpenAlexW4298110830

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.