ArticleSensors (Basel, Switzerland)2022
Calibration of a Catadioptric System and 3D Reconstruction Based on Surface Structured Light.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- An Improved TransMVSNet Algorithm for Three-Dimensional Reconstruction in the Unmanned Aerial Vehicle Remote Sensing Domain.Sensors (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
In response to the problem of the small field of vision in 3D reconstruction, a 3D reconstruction system based on a catadioptric camera and projector was built by introducing a traditional camera to calibrate the catadioptric camera and projector system. Firstly, the intrinsic parameters of the camera and the traditional camera are calibrated separately. Then, the calibration of the projection system is accomplished by the traditional camera. Secondly, the coordinate system is introduced to calculate, respectively, the position of the catadioptric camera and projector in the coordinate system, and the position relationship between the coordinate systems of the catadioptric camera and the projector is obtained. Finally, the projector is used to project the structured light fringe to realize the reconstruction using a catadioptric camera. The experimental results show that the reconstruction error is 0.75 mm and the relative error is 0.0068 for a target of about 1 m. The calibration method and reconstruction method proposed in this paper can guarantee the ideal geometric reconstruction accuracy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials