Evidence map›Paper›PMID 36236383›Full record

ArticleSensors (Basel, Switzerland)2022

Calibration of SO

Sofía Ahumada, Matias Tagle, Yeanice Vasquez, Rodrigo Donoso, Jenny Lindén, Fredrik Hallgren, Marta Segura, Pedro Oyola

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Does screw alignment affect tether breakage in vertebral body tethering?European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Sofía AhumadaAirflux, Antonio Bellet 292, Santiago 7500000, Chile.
Matias TagleIndependent Researcher, Antonio Bellet 292, Santiago 7500000, Chile.ORCID 0000-0001-7782-601X
Yeanice VasquezAirflux, Antonio Bellet 292, Santiago 7500000, Chile.
Rodrigo DonosoAirflux, Antonio Bellet 292, Santiago 7500000, Chile.ORCID 0000-0002-3380-5484
Jenny LindénIVL Swedish Environmental Research Institute, Aschebergsgatan 44, 41133 Gothenburg, Sweden.
Fredrik HallgrenIVL Swedish Environmental Research Institute, Aschebergsgatan 44, 41133 Gothenburg, Sweden.
Marta SeguraIVL Swedish Environmental Research Institute, Aschebergsgatan 44, 41133 Gothenburg, Sweden.
Pedro OyolaCentro Mario Molina Chile, Antonio Bellet 292, Santiago 7500000, Chile.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Low-cost sensors can provide inaccurate data as temperature and humidity affect sensor accuracy. Therefore, calibration and data correction are essential to obtain reliable measurements. This article presents a training and testing method used to calibrate a sensor module assembled from SO2 and NO2 electrochemical sensors (Alphasense B4 and B43F) alongside air temperature (T) and humidity (RH) sensors. Field training and testing were conducted in the industrialized coastal area of Quintero Bay, Chile. The raw responses of the electrochemical (mV) and T-RH sensors were subjected to multiple linear regression (MLR) using three data segments, based on either voltage (SO2 sensor) or temperature (NO2). The resulting MLR equations were used to estimate the reference concentration. In the field test, calibration improved the performance of the sensors after adding T and RH in a linear model. The most robust models for NO2 were associated with data collected at T < 10 °C (R2 = 0.85), while SO2 robust models (R2 = 0.97) were associated with data segments containing higher voltages. Overall, this training and testing method reduced the bias due to T and HR in the evaluated sensors and could be replicated in similar environments to correct raw data from low-cost electrochemical sensors. A calibration method based on training and sensor testing after relocation is presented. The results show that the SO2 sensor performed better when modeled for different segments of voltage data, and the NO2 sensor model performed better when calibrated for different temperature data segments.

Indexed as

Air PollutantsNitrogen DioxideCalibrationEnvironmental MonitoringHumidityAir PollutantsNitrogen Dioxidecalibrationelectrochemicalrelocation

Identifiers

PMID36236383
PMCPMC9572153

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.