ArticlePolymers2022
Highly Sensitive Liquid M-Z Waveguide Sensor Based on Polymer Suspended Slot Waveguide Structure.
Article in Polymers, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Dispersion Engineering and Sensitivity Enhancement in Photonic Crystal Waveguide Sensors: Current Advances and Emerging Challenges.Sensors (Basel, Switzerland) · 2026Review
- Photonics on a Budget: Low-Cost Polymer Sensors for a Smarter World.Micromachines · 2025Review
- Design of Suspended Slot Racetrack Microring Refractive Index Sensor Based on Polymer Nanocomposite.Polymers · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
The slot structure has great advantages in improving the sensitivity of integrated waveguide optical sensors and reducing the detection limit. We propose a polymer Mach-Zehnder interferometer (MZI) optical sensor based on the slot structure and adopted the suspended structure to improve optical field interaction with the analyte, hence boosting the sensor's sensing accuracy. In this paper, the effects of the single waveguide width, slot width, and coupling structure of the slot waveguide on the performance of the sensor operating at a 1550 nm wavelength were analyzed. Under the premise of satisfying single-mode transmission, we designed an MZI with a branch spacing of 10 µm, arm length of 2045 µm, branch span of 700 µm, and slot region of 500 µm. The sensor's average sensitivity was 972.1 dB/RIU, and its average detection resolution was 1.6 × 10
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.