Evidence map›Paper›PMID 36234281›Full record

ArticleMaterials (Basel, Switzerland)2022

Fatigue and Fracture Resistance Testing of Polyether Ether Ketone (PEEK) Implant Abutments in an Ex Vivo Chewing Simulator Model.

Babak Saravi, Anselm Flohr, Sebastian B Patzelt, Benedikt C Spies, Derek Hazard, Ralf J Kohal

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Babak SaraviDepartment of Orthopedics and Trauma Surgery, Faculty of Medicine, University of Freiburg, Medical Center-University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany.ORCID 0000-0003-2298-3696
Anselm FlohrDepartment of Prosthetic Dentistry, Faculty of Medicine, Medical Center-University of Freiburg, Center for Dental Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany.
Sebastian B PatzeltDepartment of Prosthetic Dentistry, Faculty of Medicine, Medical Center-University of Freiburg, Center for Dental Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany.ORCID 0000-0002-1434-5398
Benedikt C SpiesDepartment of Prosthetic Dentistry, Faculty of Medicine, Medical Center-University of Freiburg, Center for Dental Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany.ORCID 0000-0003-1702-1679
Derek HazardInstitute of Medical Biometry and Medical Statistics, Faculty of Medicine, Medical Center-University of Freiburg, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany.
Ralf J KohalDepartment of Prosthetic Dentistry, Faculty of Medicine, Medical Center-University of Freiburg, Center for Dental Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany.ORCID 0000-0001-7095-4190

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Polyether ether ketone (PEEK) has been introduced into implant dentistry as a viable alternative to current implant abutment materials. However, data on its physico-mechanical properties are still scarce. The present study sought to shed light on this topic utilizing an ex vivo chewing simulator model. A total of 48 titanium two-piece implants were allocated into three groups (

Indexed as

abutmentsdental implantex vivofracture resistanceloadingPEEKprostheticszirconia

Identifiers

PMID36234281
PMCPMC9573129

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.