Evidence map›Paper›PMID 36234089›Full record

ArticleMaterials (Basel, Switzerland)2022

Research on Structural Performance of Hybrid Ferro Fiber Reinforced Concrete Slabs.

Hafiz Zain Saeed, Muhammad Zubair Saleem, Yie Sue Chua, Nikolai Ivanovich Vatin

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 3 countries.

Hafiz Zain SaeedSchool of Engineering, Monash University, Jalan Lagoon Selatan, Bandar Sunway 47500, Malaysia.ORCID 0000-0002-0841-8546
Muhammad Zubair SaleemDepartment of Civil Engineering, University of Engineering and Technology, Taxila 47080, Pakistan.
Yie Sue ChuaSchool of Engineering, Monash University, Jalan Lagoon Selatan, Bandar Sunway 47500, Malaysia.ORCID 0000-0002-6611-8883
Nikolai Ivanovich VatinPeter the Great Saint Petersburg Polytechnic University, 195251 Saint Petersburg, Russia.ORCID 0000-0002-1196-8004
Monash University Malaysia · MYPeter the Great St. Petersburg Polytechnic University · RUUniversity of Engineering and Technology Taxila · PK

Funding

Ministry of Science and Higher Education of the Russian Federation under the strategic academic leadership program 'Priority 2030' Agreement 075-15-2021-1333 dated 30 September 2021
6 · The paper itself

Abstract

Reinforced concrete structures, particularly in cold areas, experience early deterioration due to steel corrosion. Fiber-Reinforced Concrete (FRC) is an emerging construction material and cost-effective substitute for conventional concrete to enhance the durability and resistance against crack development. This article examines the structural performance of hybrid ferro fiber reinforced concrete slabs (mix ratio of mortar 1:2) comprising silica fume, layers of spot-welded mesh and different ratios of polypropylene fibers. The ferrocement slabs are compared with a conventional Reinforced Cement Concrete (RCC) slab (mix ratio of 1:2:4). The experimental work comprised a total of 13 one-way slabs, one control specimen and three groups of ferrocement slabs divided based on different percentages of Poly Propylene Fibers (PPF) corresponding to 0.10%, 0.30% and 0.50% dosage in each group. Furthermore, in each group, the percentage of steel ratio in ferrocement slabs varied between 25% and 100% of the steel area in the reinforced concrete control slab specimen. For evaluating the structural performance, the observation of deflection, stress-strain behavior, cracking load and energy absorption are critical parameters assessed using LVDTs and strain gauges. At the same time, the slabs were tested in flexure mode with third point loading. The experimental results showed that the first cracking load and ultimate deflection for fibrous specimens with 0.5% fiber and 10% silica fume increased by 15.25% and 13.2% compared with the reference RCC control slab. Therefore, by increasing the percentage of PPF and steel wire mesh reinforcement in the ferrocement slab, the post-cracking behavior in terms of deflection properties and energy absorption capacity was substantially enhanced compared to the RCC control slab.

Indexed as

deflectionfailurefiber-reinforced concrete slabstress-strain curve

Identifiers

PMID36234089
PMCPMC9572473
OpenAlexW4298002555

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.