Evidence map›Paper›PMID 36233744›Full record

ArticleJournal of clinical medicine2022

Intraoral Scanning as an Alternative to Evaluate the Accuracy of Dental Implant Placements in Partially Edentate Situations: A Prospective Clinical Case Series.

Jan van Hooft, Guido Kielenstijn, Jeroen Liebregts, Frank Baan, Gert Meijer, Jan D'haese, Ewald Bronkhorst, Luc Verhamme

Abstract read
In one paragraph

Article in Journal of clinical medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jan van HooftDepartment of Dentistry, Radboudumc Nijmegen, Philips van Leydenlaan 25, 6525 EX Nijmegen, The Netherlands.ORCID 0000-0003-3157-5061
Guido KielenstijnDepartment of Dentistry, Radboudumc Nijmegen, Philips van Leydenlaan 25, 6525 EX Nijmegen, The Netherlands.
Jeroen LiebregtsDepartment of Oral and Maxillofacial Surgery, Radboudumc Nijmegen, Geert Grooteplein Zuid 10, 6525 GA Nijmegen, The Netherlands.
Frank Baan3D Lab, Radboudumc Nijmegen, Geert Grooteplein Zuid 10, 6525 GA Nijmegen, The Netherlands.
Gert MeijerDepartment of Oral and Maxillofacial Surgery, Radboudumc Nijmegen, Geert Grooteplein Zuid 10, 6525 GA Nijmegen, The Netherlands.ORCID 0000-0002-5408-2094
Jan D'haeseDepartment of Dentistry, Radboudumc Nijmegen, Philips van Leydenlaan 25, 6525 EX Nijmegen, The Netherlands.ORCID 0000-0002-2404-0483
Ewald BronkhorstDepartment of Dentistry, Radboudumc Nijmegen, Philips van Leydenlaan 25, 6525 EX Nijmegen, The Netherlands.ORCID 0000-0003-0953-8053
Luc Verhamme3D Lab, Radboudumc Nijmegen, Geert Grooteplein Zuid 10, 6525 GA Nijmegen, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

(1) Background: For years, Cone-Beam Computed Tomography’s (CBCT) have been the golden standard to evaluate implant placement accuracy. By validating Intraoral Scans (IOS) as an alternative to determine implant placement accuracy, a second CBCT could be avoided. (2) Methods: Using dynamic guided implant surgery, 23 implants were placed in 16 partially edentate patients. Preoperatively, both CBCT and IOS (Trios® 3) were obtained and subsequently imported into DTX Studio™ planning software to determine the ideal implant location. A CBCT scan and an IOS including scan abutments were acquired immediately after placement. Both postoperative CBCT and postoperative IOS were used to compare the achieved implant position with the planned implant position and were projected and analyzed using the Implant Position Orthogonal Projection (IPOP) method. (3) Results: Mean differences between the CBCT and IOS methods on the mesio−distal plane were 0.09 mm (p = 0.419) at the tip, 0.01 mm (p = 0.910) at the shoulder, −0.55° (p = 0.273) in angulation, and 0.2 mm (p = 0.280) in implant depth. Mean differences between both methods on the bucco-lingual/bucco-palatal plane were 0.25 mm (p = 0.000) at the tip, 0.12 mm (p = 0.011) at the shoulder, −0.81° (p = 0.002) in angulation, and 0.17 mm (p = 0.372) in implant depth. A statistical analysis was performed using a paired t-test. All mesiodistal deviations between the two methods showed no significant differences (p > 0.05). Buccolingual/buccopalatal deviations showed no significant difference in implant depth deviation. However, significant differences were found at the tip, shoulder, and angulation (p < 0.05). These values are of minimal clinical significance. (4) Conclusions: This study supports the hypothesis that a postoperative IOS is a valid alternative for determining implant placement accuracy.

Indexed as

accuracycone-beam computed tomographyintraoral scanoral implantologyoral surgery

Identifiers

PMID36233744
PMCPMC9572334

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.